Correlation of pressure and displacement during gingival displacement: An in vitro study.

J Prosthet Dent

Research Fellow, Department of Physics, University of Otago, Dunedin, New Zealand.

Published: March 2016

Statement Of Problem: Although numerous gingival displacement materials are available, information is limited regarding the pressures that can atraumatically produce sufficient gingival displacement for a successful impression.

Purpose: The purpose of this in vitro study was to measure pressure and the resulting movement of artificial gingiva during simulated gingival displacement.

Material And Methods: An idealized tooth model was made from acrylic resin and polyvinyl siloxane to simulate the free gingiva, sulcus, and attachment. The pressure and displacement achieved by 3 materials (Expasyl, Expasyl New, and KnitTrax Cord) were measured. A stereoscopic digital measuring microscope was used to quantify the space generated by the displacement material. A pressure gauge was used to measure the corresponding pressures.

Results: The injection of Expasyl resulted in a displacement distance of 1.31 mm, Expasyl New 1.07 mm, and KnitTrax Cord 0.85 mm, which are within acceptable clinical parameters. The correlation between pressure and gap showed that Expasyl and Expasyl New behaved similarly, while KnitTrax Cord was different. Expasyl, Expasyl New, and KnitTrax Cord all had maximum pressures that would be considered atraumatic to the epithelial attachment.

Conclusions: An increase in pressure resulted in an increase in displacement for the 2 paste materials. However, contrary to expectation, displacement decreased as pressure increased for the cord material.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2015.08.008DOI Listing

Publication Analysis

Top Keywords

knittrax cord
16
gingival displacement
12
expasyl expasyl
12
displacement
9
correlation pressure
8
pressure displacement
8
expasyl
8
expasyl knittrax
8
pressure
6
cord
5

Similar Publications

Statement Of Problem: Although numerous gingival displacement materials are available, information is limited regarding the pressures that can atraumatically produce sufficient gingival displacement for a successful impression.

Purpose: The purpose of this in vitro study was to measure pressure and the resulting movement of artificial gingiva during simulated gingival displacement.

Material And Methods: An idealized tooth model was made from acrylic resin and polyvinyl siloxane to simulate the free gingiva, sulcus, and attachment.

View Article and Find Full Text PDF

A comparison of pressure generated by cordless gingival displacement techniques.

J Prosthet Dent

June 2012

Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin, New Zealand.

Statement Of Problem: Handling properties of cordless gingival displacement materials is not well understood, resulting in incorrect use. Insufficient displacement of the gingival margin may result in a poor impression.

Purpose: This study investigated the pressure generated by a cordless displacement paste with respect to different techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!