(131)I is widely used in Latin America and Caribbean Region in the field of nuclear medicine and has been recognised as one of the main sources of potential intake of radionuclides by the staff. The In Vivo Monitoring laboratory of the Institute for Radiation Protection and Dosimetry (IRD-CNEN-Brazil) organised three intercomparison exercises (2005, 2009 and 2013) in the scope of IAEA technical cooperation projects RLA9049 and RLA9066 aimed to disseminate and harmonise the technique for measuring (131)I in the human thyroid. The number of participants in Latin America increased from 9 to 20 institutions from 7 and 13 countries, respectively, over the last 10 y. The participants have improved significantly their ability on the in vivo measurement technique. In the 2013 round all laboratories which reported results presented performances in an acceptable range according to the ISO criteria indicating the benefit of such exercises in the region.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncv455 | DOI Listing |
Int J Radiat Biol
January 2025
Laboratory of Biological Dose Assessment, National Radiation Emergency Medicine, Korea Institute of Radiological & Medical Sciences, Seoul, Republic of Korea.
Purpose: Biological dosimetry is an essential analytic method to estimate the absorbed radiation dose in the human body by measuring changes in biomolecules after radiation exposure. Joint response in a network to mass-casualty radiation incidents is one way to overcome the limitations of biological dosimetry, sharing the workload among laboratories. This study aimed to investigate the current performance, collaborative activities and technical advances of the Korea biodosimetry network (K-BioDos), and suggest the future directions toward successful joint response.
View Article and Find Full Text PDFAppl Radiat Isot
December 2024
Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Fontenay-aux-Roses, France.
This paper presents the results of the first intercomparison exercise on Electron Paramagnetic Resonance (EPR) dosimetry using sorbitol, where the performance parameters of sorbitol as dosimetric material were evaluated by three independent participants. Each participant was asked to determine a calibration curve using a set of sorbitol powder samples irradiated to four different doses (1.00, 2.
View Article and Find Full Text PDFThis study presents what we believe is the first extensive assessment of the water reflectance products from the German hyperspectral Environmental Mapping and Analysis Program (EnMAP). We evaluate EnMAP's standard normalized water leaving reflectance [ρ] over 17 water sites in the first two years of the mission. The EnMAP [ρ] standard product is generated by a dedicated water atmospheric correction (AC) called the Modular Inversion Program (MIP).
View Article and Find Full Text PDFSci Total Environ
December 2024
Department of Pharmacology, Pharmacognosy and Botany, Faculty of Pharmacy, Complutense University of Madrid, Madrid, Spain. Electronic address:
Interest in biological air quality monitoring is rising, and updated public information is increasingly demanded by stakeholders in the case of airborne pollen, which requires maintaining high standards of data quality. The number of aerobiological stations worldwide is continuously growing, and quality management is becoming more complex with the increase in the scale of aerobiological networks. Quality control exercises are crucial for maintaining the quality of the data used in the pollen monitoring routine over time.
View Article and Find Full Text PDFMolecules
September 2024
Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Avenida Complutense 40, 28040 Madrid, Spain.
Thorium is a radionuclide used in various environmental studies such as dating, sediment movement, soil-plant transfer studies, and contamination of waste from the natural fuel cycle. The liquid-liquid extraction method using tri-n-butyl phosphate (TBP) allows for the separation of Th from the accompanying actinides. However, the separation of Th and U present in the same sample is not trivial.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!