Visual Outcomes after Proton Beam Irradiation for Choroidal Melanomas Involving the Fovea.

Ophthalmology

Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, Massachusetts. Electronic address:

Published: February 2016

Purpose: To report visual outcomes in patients undergoing proton beam irradiation of tumors located within 1 disc diameter of the fovea.

Design: Retrospective review.

Participants: Patients with choroidal melanoma involving the fovea treated with proton beam therapy between 1975 and 2009.

Methods: Three hundred fifty-one patients with choroidal melanomas located 1 disc diameter (DD) or less from the fovea and more than 1 DD away from the optic nerve were included in this study. In a subgroup of 203 of the patients with small and medium choroidal melanomas, the effect of a reduced dose of radiation, 50 Gy (relative biological effectiveness [RBE]) versus 70 Gy (RBE), on visual outcomes was analyzed. The Kaplan-Meier method and Cox regression analysis were performed to calculate cumulative rates of vision loss and to assess risk factors for vision loss, respectively.

Main Outcome Measures: Visual acuity and radiation complications, which included radiation maculopathy, papillopathy, retinal detachment, and rubeosis, were assessed.

Results: Three hundred fifty-one patients were included in this study with a mean follow-up time of 68.7 months. More than one-third of patients (35.5%) retained 20/200 or better vision 5 years after proton beam irradiation. For those patients with a baseline visual acuity of 20/40 or better, 16.2% of patients retained this level of vision 5 years after proton beam irradiation. Tumor height less than 5 mm and baseline visual acuity 20/40 or better were associated significantly with a better visual outcome (P < 0.001). More than two-thirds (70.4%) of patients receiving 50 Gy (RBE) and nearly half (45.1%) of patients receiving 70 Gy (RBE) retained 20/200 or better vision 5 years after treatment, but this difference was not significant. Approximately 20% of patients with these smaller macular tumors retained 20/40 vision or better 5 years after irradiation.

Conclusions: The results of this retrospective analysis demonstrate that despite receiving a full dose of radiation to the fovea, many patients with choroidal melanoma with foveal involvement maintain useful vision. A radiation dose reduction from 70 to 50 Gy (RBE) did not seem to increase the proportion of patients who retain usable vision.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ophtha.2015.09.031DOI Listing

Publication Analysis

Top Keywords

proton beam
20
beam irradiation
16
patients
13
visual outcomes
12
choroidal melanomas
12
patients choroidal
12
visual acuity
12
vision years
12
involving fovea
8
located disc
8

Similar Publications

The sarcoma ring trial: a case-based analysis of inter-center agreement across 21 German-speaking sarcoma centers.

J Cancer Res Clin Oncol

January 2025

Sarcoma Unit, Department of Surgery, University Medical Center and Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.

Purpose: The management of soft tissue sarcoma (STS) at reference centers with specialized multidisciplinary tumor boards (MTB) improves patient survival. The German Cancer Society (DKG) certifies sarcoma centers in German-speaking countries, promoting high standards of care. This study investigated the variability in treatment recommendations for localized STS across different German-speaking tertiary sarcoma centers.

View Article and Find Full Text PDF

A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.

In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).

View Article and Find Full Text PDF

Orthotopic tumor models in pre-clinical translational research are becoming increasingly popular, raising the demands on accurate tumor localization prior to irradiation. This task remains challenging both in X-ray and proton computed tomography (xCT and pCT, respectively), due to the limited contrast of tumor tissue compared to the surrounding tissue. We investigate the feasibility of gadolinium oxide nanoparticles as multimodal contrast enhancement agent for both imaging modalities.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to investigate the fundamental properties of spot-scanning proton beams and compare them to Monte Carlo (MC) simulations, both with and without CT calibration, using spatially diverse combinations of materials.

Methods: A heterogeneous phantom was created by spatially distributing titanium, wax, and thermocol to generate six scenarios of heterogeneous combinations. Proton pencil beams ranging in energy from 100 to 226.

View Article and Find Full Text PDF
Article Synopsis
  • Proton Minibeam Radiation Therapy has been promising in enhancing treatment efficacy compared to traditional radiation, but more research into its biological mechanisms is needed.
  • A mechanical collimation setup was developed to produce 250µm minibeams with a 1000µm spacing, with optimization using Monte Carlo simulations conducted at various proton therapy sites.
  • Results showed a peak-to-valley dose ratio (PVDR) of 10 in Dresden and 14 in Seattle, with some discrepancies between dosimetry methods that can be addressed with correction factors.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!