[Breast imaging of mass, architectural distortion and asymmetry: Clinical practice guidelines].

J Gynecol Obstet Biol Reprod (Paris)

Hôpital de Hautepierre, unité de sénologie, hôpitaux universitaires, avenue Molière, 67200 Strasbourg, France. Electronic address:

Published: December 2015

The development of the mammary imaging (mammography, ultrasound, MRI) enables the discovery of more and more lesions. The BI-RADS lexicon is the reference book for their descriptive analysis. Four elementary images must be individualized: masses and architectural distortion described in 3 imaging techniques, asymmetries and microcalcifications described in mammography. The aim of this work was to review three of these images: mass, architectural distortion and asymmetry, allowing the various actors involved in senology to propose an up-to-date diagnostic and interventional strategy, based on their positive predictive values (PPV) or negative predictive values of cancer and allowing the classification BI-RADS of the lesion. The masses are the most often encountered lesions as well in screening as in diagnosis. Their PPV is superior in diagnosis than in screening and it increases with the age. Their irregular forms, their spiculated outlines and their evolutionary character are the most relevant elements of suspicion. The architectural distortion is the rarest image and always classified suspect BI-RADS 4, except in case of a known scar. The asymmetry is less common; its PPV is low and rises only in case of evolutionary asymmetry.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jgyn.2015.09.056DOI Listing

Publication Analysis

Top Keywords

architectural distortion
16
mass architectural
8
distortion asymmetry
8
predictive values
8
[breast imaging
4
imaging mass
4
architectural
4
distortion
4
asymmetry
4
asymmetry clinical
4

Similar Publications

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Phase-contrast micro-tomography ([Formula: see text]CT) with synchrotron radiation can aid in the differentiation of subtle density variations in weakly absorbing soft tissue specimens. Modulation-based imaging (MBI) extracts phase information from the distortion of reference patterns, generated by periodic or randomly structured wavefront markers (e.g.

View Article and Find Full Text PDF

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Sensitive detection of formaldehyde a luminescent distorted EuL tetrahedral cage.

Chem Commun (Camb)

January 2025

College of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China.

A distorted low-symmetry EuL tetrahedral cage was fabricated through the self-assembly of europium ions and -symmetric bowl-shaped ligands containing a phosphangulene core. X-ray crystallography confirmed its unique architecture, featuring significant structural distortion and solvent-accessible coordination sites. This cage showcases exceptional luminescence-based sensitivity for formaldehyde detection compared to other analogs, achieving an impressive detection limit of 19.

View Article and Find Full Text PDF

Cobalt-based oxides have attracted significant attention as p-type thermoelectric materials due to their wide operational temperature range. However, their low average figure of merit () value has hindered service performance. A series of cation vacancies as Ca-active sites were introduced into CaCoO (0 ≤ ≤ 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!