We evaluated the intra- and inter-observer reliability and criterion validity of an observation protocol, developed in an iterative process involving practicing ergonomists, for assessment of working technique during cash register work for the purpose of preventing upper extremity symptoms. Two ergonomists independently assessed 17 15-min videos of cash register work on two occasions each, as a basis for examining reliability. Criterion validity was assessed by comparing these assessments with meticulous video-based analyses by researchers. Intra-observer reliability was acceptable (i.e. proportional agreement >0.7 and kappa >0.4) for 10/10 questions. Inter-observer reliability was acceptable for only 3/10 questions. An acceptable inter-observer reliability combined with an acceptable criterion validity was obtained only for one working technique aspect, 'Quality of movements'. Thus, major elements of the cashiers' working technique could not be assessed with an acceptable accuracy from short periods of observations by one observer, such as often desired by practitioners. Practitioner Summary: We examined an observation protocol for assessing working technique in cash register work. It was feasible in use, but inter-observer reliability and criterion validity were generally not acceptable when working technique aspects were assessed from short periods of work. We recommend the protocol to be used for educational purposes only.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00140139.2015.1098734DOI Listing

Publication Analysis

Top Keywords

working technique
24
criterion validity
20
reliability criterion
16
cash register
16
register work
16
inter-observer reliability
16
observation protocol
12
validity observation
8
technique cash
8
reliability acceptable
8

Similar Publications

The widespread use of pesticides, including diazinon, poses an increased risk of environmental pollution and detrimental effects on biodiversity, food security, and water resources. In this study, we investigated the impact of Potentially Toxic Elements (PTE) including Zn, Cd, V, and Mn on the degradation of diazinon in three different soils. We investigated the capability and performance of four machine learning models to predict residual pesticide concentration, including adaptive neuro-fuzzy inference system (ANFIS), support vector regression (SVR), radial basis function (RBF), and multi-layer perceptron (MLP).

View Article and Find Full Text PDF

An effective surgical educational system in the era of robotic surgery: "Double-Surgeon Technique" in robotic gastrectomy for minimally invasive surgery.

Langenbecks Arch Surg

December 2024

Department of Gastroenterological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-Cho, Kita-Ku, Okayama City, Okayama, 700-8558, Japan.

Purpose: Gastric cancer (GC) remains a major malignancy. Robotic gastrectomy (RG) has gained popularity due to various advantages. Despite those advantages, many hospitals lack the necessary equipment for RG and are still performing laparoscopic gastrectomy (LG) due to its established minimal invasiveness and safety.

View Article and Find Full Text PDF

The current study investigates and compares the biological effects of ultrathin conformal coatings of zirconium dioxide (ZrO) and vanadium pentoxide (VO) on osteoblastic MG-63 cells grown on TiO nanotube layers (TNTs). Coatings were achieved by the atomic layer deposition (ALD) technique. TNTs with average tube diameters of 15, 30, and 100 nm were fabricated on Ti substrates (via electrochemical anodization) and were used as primary substrates for the study.

View Article and Find Full Text PDF

Purpose: To explore the experiences of long-term sick-listed employees and those of employers with communication and collaboration during sick leave and the return-to-work (RTW) process.

Methods: Previously long-term sick-listed employees ( = 9) and employers ( = 9) were interviewed about their experiences with communication and collaboration during sick leave and RTW. Thematic analysis, utilizing patient journey mapping was applied to analyze and map out their experiences.

View Article and Find Full Text PDF

In endoscopic endonasal surgery for anterior skull base lesions, maximizing the anterior sphenoidotomy in the superior part is crucial for direct visualization and creating a wide working corridor. Here, we describe a technique we devised that maximizes upper anterior sphenoidotomy while preserving the olfactory mucosa. Laryngoscope, 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!