A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[A simple preparation method of an electric heating apparatus for heating capillary chromatographic columns and its application in liquid chromatography-mass spectrometry system]. | LitMetric

For deep coverage of proteome, especially in performing qualitative identification and quantitative analysis of low-abundance proteins, the most commonly used method is the application of a longer capillary chromatographic column or a capillary column packed with smaller particle sizes. However, this causes another problem, the very high back pressure which results in liquid leaks in some connection parts in a liquid chromatograph. To solve this problem, an electric heating apparatus was developed to raise the temperature of a capillary column for reducing its back pressure, which was further applied in a capillary high performance liquid chromatography-tandem mass spectrometry system (cHPLC-MS/MS), and evaluated in the terms of chromatographic column back pressure and chromatographic column efficiency using bovine serum albumin (BSA) tryptic digests and yeast tryptic digests, separately. The results showed that at the optimum current, our electric heating apparatus could reduce the column pressure of a capillary column packed with 3 µm packing materials by at least 50% during the separation of BSA tryptic digestion and yeast tryptic digestion, compared with that without electric heating. The column efficiency was also increased slightly. This suggested that the electric heating apparatus can significantly reduce the column pressure, which provides an efficient way to use capillary chromatographic columns packed with smaller sizes of particles at a lower pressure.

Download full-text PDF

Source
http://dx.doi.org/10.3724/sp.j.1123.2015.01036DOI Listing

Publication Analysis

Top Keywords

electric heating
20
heating apparatus
16
capillary chromatographic
12
chromatographic column
12
capillary column
12
column pressure
12
column
9
chromatographic columns
8
column packed
8
packed smaller
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!