A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Perioperative Outcomes of Minimally Invasive Aortic Valve Replacement through Right Anterior Minithoracotomy. | LitMetric

Background The aim of the study was to analyze perioperative outcomes after minimally invasive aortic valve replacement through right anterior minithoracotomy (RAT-AVR). Patient selection criteria, anesthesia protocol, and surgical technique are presented. Methods A retrospective analysis of 194 patients electively scheduled for RAT-AVR was performed between January 2009 and June 2013. For preoperative planning, computed tomography was performed. Results Among studied patients, there were 48.5% females and 51.5% males with a mean age of 69.9 ± 9.2 years. The predicted mortality calculated with EuroSCORE II was 3.2 ± 0.9%, and observed mortality of RAT-AVR patients was 1.5%. Finally, RAT-AVR surgery was performed on 97.9% of patients (n = 190). Reasons for conversions to median sternotomy were bleeding from aortotomy site (n = 4) and from the right ventricle after epicardial pacing wire placement (n = 1), pleural adhesions (n = 2), and ascending aorta hidden under the sternum (n = 2). The second intercostal space was chosen for surgical access in 97.9% of patients.There were 3.6% reoperations for bleeding: aortotomy place (n = 1), epicardial pacing wire placement (n = 3), right lung tear (n = 2), and intercostal vessels (n = 1). The intensive care unit and hospital length of stays were 1.3 ± 1.2 and 5.7 ± 1.4 days, respectively. Strokes were present in 1.5% of patients. The perioperative complications rate diminished with time, occurring in 44.9% of the patients between 2009 and 2010 and in 15.6% of patients in 2013. Conclusions RAT-AVR can be safely performed without increased morbidity and mortality. Reduced complication rates over time reflect a learning curve.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0035-1566129DOI Listing

Publication Analysis

Top Keywords

perioperative outcomes
8
outcomes minimally
8
minimally invasive
8
invasive aortic
8
aortic valve
8
valve replacement
8
replacement anterior
8
anterior minithoracotomy
8
bleeding aortotomy
8
epicardial pacing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!