A stereotaxic apparatus for the study of the central nervous structures in the pig.

Brain Res Bull

Unité de Neurobiologie des régulations nutritionnelles, Station de Physiologie de la Nutrition, I.N.R.A., Jouy en Josas, France.

Published: March 1989

An apparatus has been developed derived from the Horsley-Clarke principle. Specific requirement was to use large breeds of pigs from weaning to adult age (5 to 120 kg). The pig auditory canals are oblique; the measurement of the corresponding angles was achieved by means of two interconnected barrels, used afterwards to fix the ear-bars. The wide variability of the skull morphology led to the systematic use of ventriculography with a liquid of contrast. Consequently the pieces allowing the head fixation in the stereotaxic apparatus were designed to avoid any shadow on the brain area. As it was not always possible to localize the commissura anterior, the anterior border of the recessus preopticus was chosen to determine, together with the commissura posterior, the reference horizontal plane. The antero-posterior coordinates were counted from the anterior border of the commissura posterior. The methodology, which has been tested in a wide range of pigs, is discussed in relation with the methods used for other animal species.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0361-9230(89)90118-4DOI Listing

Publication Analysis

Top Keywords

stereotaxic apparatus
8
anterior border
8
commissura posterior
8
apparatus study
4
study central
4
central nervous
4
nervous structures
4
structures pig
4
pig apparatus
4
apparatus developed
4

Similar Publications

An MRI-guided stereotactic neurosurgical robotic system for semi-enclosed head coils.

J Robot Surg

December 2024

National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, 100084, China.

Magnetic resonance imaging (MRI) offers high-quality soft tissue imaging without radiation exposure, which allows stereotactic techniques to significantly improve outcomes in cranial surgeries, particularly in deep brain stimulation (DBS) procedures. However, conventional stereotactic neurosurgeries often rely on mechanical stereotactic head frames and preoperative imaging, leading to suboptimal results due to the invisibility and the contact with patient's head, which may cause additional harm. This paper presents a frameless, MRI-guided stereotactic neurosurgical robotic system.

View Article and Find Full Text PDF

SARS-CoV-2 membrane protein induces neurodegeneration via affecting Golgi-mitochondria interaction.

Transl Neurodegener

December 2024

Department of Neurosciences, Hengyang Medical School, University of South China, Hengyang, 421009, China.

Background: Neurological complications are a significant concern of Coronavirus Disease 2019 (COVID-19). However, the pathogenic mechanism of neurological symptoms associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection is poorly understood.

Methods: We used Drosophila as a model to systematically analyze SARS-CoV-2 genes encoding structural and accessory proteins and identified the membrane protein (M) that disrupted mitochondrial functions in vivo.

View Article and Find Full Text PDF

Opto-Avoidance-Elevated Plus Maze protocol to study positive or negative valence upon optogenetic stimulation in the mouse brain.

STAR Protoc

December 2024

Uppsala University, Department of Organism Biology, 752 36 Uppsala, Sweden; Aligning Science Across Parkinson's (ASAP) Collaborative Research Network, Chevy Chase, MD 20815, USA; Lund University, Department of Experimental Medical Science, Box 118, 221 00 Lund, Sweden. Electronic address:

The elevated plus maze (EPM) apparatus consists of two open arms that provide aversive spaces and two closed arms that provide protective and welcoming spaces. Here, we present a protocol to implement the classical EPM apparatus in a real-time optogenetic environment to address behavioral avoidance in mice. We describe steps for performing stereotaxic surgery, mouse manipulation, and experimental setup.

View Article and Find Full Text PDF
Article Synopsis
  • Robotics in neurosurgery is increasingly used, particularly with the incorporation of intraoperative imaging for precise patient registration in a new lightweight, table-mounted robotic system designed for cranial biopsies and sEEG procedures.
  • The study evaluated 26 patients using the Cirq system for stereotactic biopsy or sEEG from January 2023 to August 2024, comparing results with data from the frameless VarioGuide system, specifically looking at entry errors, target errors, and vector deviation of electrodes.
  • Results indicated that Cirq-assisted procedures had a mean surgical time of about 117 minutes for biopsies and 269 minutes for sEEG, revealing differences in efficiency compared to VarioGuide, where the comparable
View Article and Find Full Text PDF

Development of a murine laser interstitial thermotherapy system.

Neurosurg Focus

November 2024

1Lillian S. Wells Department of Neurosurgery, University of Florida, Gainesville, Florida; and.

Objective: The objective of this study was to develop a murine system for the delivery of laser interstitial thermotherapy (LITT) with probe-based thermometry as a model for human glioblastoma treatment to investigate thermal diffusion in heterogeneous brain tissue.

Methods: First, the tissue heating properties were characterized using a diode-pumped solid-state near-infrared laser in a homogeneous tissue model. The laser was adapted for use with a repurposed stereotactic surgery frame utilizing a micro laser probe and Hamilton syringe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!