Background: Biomechanical studies have reported that the posterior cruciate ligament (PCL) functions as a restraint against excessive tibial internal rotation at higher degrees of knee flexion.

Purpose: To investigate the use of a supine internal rotation (IR) test for the diagnosis of grade III PCL injuries. The hypothesis was that internal rotation would be greater in patients with grade III PCL injuries compared with other knee injuries and that the supine IR test would demonstrate excellent diagnostic accuracy.

Study Design: Cohort study (diagnosis); Level of evidence, 2.

Methods: A consecutive series of 309 patients underwent arthroscopic and/or open knee ligament reconstruction surgery. Seven patients were excluded based on the inability to perform a side-to-side comparison of internal rotation. Tibial internal rotation was assessed bilaterally on 302 patients during examination under anesthesia by a single orthopaedic surgeon measuring tibial tubercle excursion (mm) while applying internal rotation torque. Internal rotation was graded from 0 to 4 at 60°, 75°, 90°, 105°, and 120° of knee flexion. Data were collected and stored prospectively. The optimal threshold for the supine IR test was chosen based on maximization of the Youden index. Diagnostic accuracy parameters were calculated. Multiple logistic regression models were constructed to assess the influence of other knee pathologies on diagnostic accuracy.

Results: Examination of the 22 PCL-deficient knees demonstrated an increase in tibial internal rotation at 60°, 75°, 90°, 105°, and 120° of knee flexion. The supine IR test had a sensitivity of 95.5%, a specificity of 97.1%, a positive predictive value of 72.4%, and a negative predictive value of 99.6% for the diagnosis of grade III PCL injuries. Posterolateral corner injury had a significant interaction with the supine IR test, increasing its sensitivity and decreasing its specificity.

Conclusion: PCL-deficient knees demonstrated an increase in the side-to-side difference in tibial internal rotation compared with other knee pathologies. The supine IR test offers high sensitivity and specificity for grade III PCL injuries and may represent a useful adjunct for diagnosing PCL injuries.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4555611PMC
http://dx.doi.org/10.1177/2325967115572135DOI Listing

Publication Analysis

Top Keywords

internal rotation
44
tibial internal
20
grade iii
20
pcl injuries
20
supine test
20
iii pcl
16
rotation
11
internal
10
supine internal
8
rotation test
8

Similar Publications

Moroccan Adaptation of the 'Self-Care Behaviour Assessment Scale' for Arteriovenous Fistula in Haemodialysis.

J Ren Care

March 2025

Faculty of Sciences Semlalia, Laboratory of Pharmacology, Neurobiology, Anthropobiology and Environment, Cadi Ayyad University, Marrakech, Morocco.

Background: Arteriovenous fistula self-care behaviours in patients receiving haemodialysis are essential to maintain patency of vascular access and prevent its life-threatening complications. Assessing arteriovenous fistula self-care behaviours in patients receiving haemodialysis requires a reliable and valid tool.

Objective: The aim of this study was to adapt and translate the Portuguese scale for the assessment of self-care behaviours of arteriovenous fistula in patients receiving haemodialysis into the Moroccan dialect and evaluate its psychometric properties in the Moroccan context.

View Article and Find Full Text PDF

Influence of pelvic position on shoulder range of motion.

BMC Musculoskelet Disord

January 2025

Lecturer of Physical Therapy, Basic Science Department, Faculty of Physical Therapy, Suez University, Suez, Egypt.

Background: pelvis and shoulder are deeply integrated. They are connected by myofascial slings. The pelvic and spinal posture affects the position of the scapula and the activity of its muscles and affects acromio-humeral distance and so that affects shoulder movement.

View Article and Find Full Text PDF

Background: Frozen shoulder (FS) is a debilitating inflammatory condition affecting the shoulder capsule that causes significant pain and stiffness. Its etiology, pathophysiology, and treatment remain poorly understood. Although regarded as self-limiting, FS can have profound implications on the activities of daily living and usually takes 1-4 years to resolve on its own accord.

View Article and Find Full Text PDF

Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.

Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.

View Article and Find Full Text PDF

Background: To analyze the biomechanical and functional characteristics of different maxillary fixation techniques after Le Fort I osteotomy and occlusal plane rotation, using the finite element method to simulate the mechanical behavior of three different osteosynthesis approaches.

Material And Methods: This is a virtual experimental study carried out using finite element analysis to compare three different osteosynthesis techniques after Le Fort I osteotomy and rotation of the maxillary occlusal plane. Three configurations were tested: four-point fixation with "L" plates (C1), two-point fixation with "L" plates (C2), and two-point fixation with pre-modeled Lindorf plates (C3).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!