Background: Injuries to the glenoid labrum frequently require repair with anchors. Placing anchor devices arthroscopically can be challenging, and anchor malpositioning can complicate surgical outcomes.
Purpose: To determine the safe insertion range and optimal insertion angle of glenoid labral anchors at various positions on the glenoid rim and to establish surgical guidelines that minimize risk of anchor perforation.
Study Design: Descriptive laboratory study.
Methods: Three-dimensional computed tomography scans of 30 normal cadaveric specimens were obtained. A virtual model of a generic labral anchor was inserted into the rim of the glenoid at the clockface positions represented by 12:00, 1:30, 3:00, 4:30, 6:00, 7:30, 9:00, and 10:30. At each position, the safe insertion range was the maximal range measured, and the optimal insertion angle was identified as the angle between the bisector of the safe insertion range and the glenoid face.
Results: Progressing in the clockwise direction, beginning at the 12:00 position, the safe insertion ranges (mean ± SD ) were 55.9° ± 10.6°, 63.6° ± 17.6°, 47.7° ± 9.1°, 46.1° ± 8°, 73.9° ± 9.7°, 40.9° ± 6.5°, 40.4° ± 7.4°, and 39.9° ± 7.1°, respectively. The optimal insertion angles were 47.9° ± 7.6°, 53.1° ± 10.9°, 35.0° ± 4.4°, 42.4° ± 4.9°, 60.9° ± 8.4°, 36.6° ± 5.9°, 31.2° ± 4.9°, 34.8° ± 4.6°, respectively.
Conclusion: Optimal insertion angles and safe insertion ranges varied significantly with respect to the position on the glenoid face. The safe insertion range and optimal insertion angle were found to be wider at the anterior glenoid as compared with the posterior glenoid. A posterolateral insertion angle was safer than an anterior insertion angle at the 10:30 position.
Clinical Relevance: Proper arthroscopic technique resulting in anchor insertion at the correct angle, depth, and location will prevent anchor-related glenohumeral complications such as glenoid perforation, cartilage damage, persistent pain, decreased range of motion, and failure of the reconstruction.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4555554 | PMC |
http://dx.doi.org/10.1177/2325967114556257 | DOI Listing |
J Vis Exp
December 2024
Department of General Surgery (Hepatobiliary, Pancreatic and Splenic Surgery), The Sixth Affiliated Hospital, Sun Yat-sen University; Biomedical Innovation Center, The Sixth Affiliated Hospital, Sun Yat-sen University;
Robot-assisted pancreaticobiliary junction resection is a surgical technique employed to treat benign duodenal tumors. The procedure involves several key steps: making a longitudinal incision in the duodenum, excising the tumor at the pancreaticobiliary junction, inserting a biliary stent, connecting the biliary and duodenal mucosa, and suturing the duodenal incision during phase I. The robotic system enhances visibility, facilitates precise operations, minimizes duodenal traction injuries to the duodenum and surgical trauma, ensures accurate suture and fixation of bile duct stents, connects the bile duct and duodenal mucosa and reduces postoperative recovery time.
View Article and Find Full Text PDFCureus
December 2024
Department of Urology, University of Miami Miller School of Medicine, Miami, USA.
Insertion of inflatable penile prosthesis (IPP) is generally regarded as a safe procedure, with low rates of complications. However, when complications do arise, they can pose significant challenges to both patients and surgeons. Patient optimization and adherence to specific intraoperative protocols are crucial in mitigating the risk of surgical complications.
View Article and Find Full Text PDFJ Clin Orthop Trauma
January 2025
Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, 2160 South First Avenue, 60153, Maywood, IL, USA.
Introduction: Mobile-bearing (MB) inserts, designed to minimize aseptic loosening and to reduce contact stresses leading to polyethylene wear, are an alternative to fixed-bearing (FB) inserts. Most studies have shown no significant difference between MB and FB constructs, and there is limited long-term data comparing the two constructs [1,2,3,4]. The purpose of this study was to report the outcomes of a randomized controlled trial comparing MB versus FB inserts on patients with minimum 20-year follow-up.
View Article and Find Full Text PDFActa Med Philipp
November 2024
Division of Thoracic, Cardiac and Vascular Surgery, Department of Surgery, College of Medicine and Philippine General Hospital, University of the Philippines Manila.
Objective: To describe the treatment outcomes of patients who underwent Percutaneous Transluminal Angioplasty (PTA) for Central Vein Occlusive Disease (CVOD) in end-stage kidney disease and determine the association between patient profile and treatment outcomes.
Methods: A single-institution, retrospective review of patients aged 18 and above with end-stage kidney disease who underwent PTA for CVOD in the University of the Philippines - Philippine General Hospital (UP-PGH) from January 1, 2013, to December 31, 2022, was performed. These patients' demographic and clinical profiles were evaluated using means, frequencies, and percentages.
Nat Commun
January 2025
CIRI, Centre International de Recherche en Infectiologie Univ Lyon, Inserm, U1111, Université Claude Bernard Lyon 1, CNRS, UMR5308, ENS de Lyon, F-69007, Lyon, France.
Prime Editing can rewrite genes in living cells by allowing point mutations, deletions, or insertion of small DNA sequences with high precision. However, its safe and efficient delivery into human stem cells remains a technical challenge. In this report, we engineer Nanoscribes, virus-like particles that encapsidate ribonucleoprotein complexes of the Prime Editing system and allow their delivery into recipient cells.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!