Objective: The AO classification for fractures of the long bones in the pediatric population was developed and validated in 2006. However, the complexity of this system has limited its use in clinical practice and few studies in the literature have evaluated its reproducibility and applicability. The present study had the objective of determining the intra and interobserver agreement using the pediatric AO system, among physicians with different levels of experience.

Methods: After making the sample calculation, 108 consecutive radiographs on long-bone fractures in patients aged 0-16 years, coming from the digital files of the quaternary-level hospital, were selected. The radiographs were classified by five examiners with different levels of experience after prior explanations about the system. A chart containing images from the classification was made available for consultation. The evaluations were made at two different times by each observer. The Fleiss kappa index was used to ascertain the intra and interobserver agreement.

Results: Intraobserver agreement that was at least substantial was obtained for all the items of the classification and it reached excellent levels for all observers in relation to five of the seven items considered. The interobserver evaluation presented excellent levels of agreement in two items, substantial in two items, moderate to substantial in one item and poor to moderate in one item. No influence from the observer's experience was observed with regard to obtaining higher or lower levels of agreement, either in the intraobserver or in the interobserver evaluation.

Conclusions: In this study, the intra and interobserver agreement was considered to be good or excellent for the pediatric AO classification system, for the parameters of bone, segment, paired bone, subsegment, standard and deviation. However, the intra and interobserver agreement was statistically unsatisfactory for the parameter of severity/side of avulsion. The levels of agreement obtained did not depend on the observer's level of experience within pediatric orthopedics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4610979PMC
http://dx.doi.org/10.1016/j.rboe.2015.08.001DOI Listing

Publication Analysis

Top Keywords

intra interobserver
20
interobserver agreement
12
levels agreement
12
classification system
8
fractures long
8
long bones
8
bones pediatric
8
pediatric population
8
substantial items
8
excellent levels
8

Similar Publications

Introduction: Patellar fractures are rare at 1% incidence of all fractures. However, they can cause significant functional impairments due to the patella's role in knee joint extension. Current scoring systems lack objectivity in assessing patellar healing.

View Article and Find Full Text PDF

Introduction: In pediatric urology, urodynamic studies are considered the most reliable method for assessing the function of the lower urinary tract. These evaluations play a particularly important role in guiding treatment decisions for neurogenic bladder conditions.

Objective: The aim of this study is to assess the impact of artifacts on the interobserver and intraobserver agreement in the interpretation of pediatric urodynamic traces.

View Article and Find Full Text PDF

Defining Normal Enthesis Stiffness Range in A Healthy Adult Population.

Br J Radiol

December 2024

Rheumatology Unit, Department of Internal Medicine, Faculty of Medicine, Universiti Teknologi MARA, 47000, Sungai Buloh, Malaysia.

Objectives: This study explores the correlation between volunteer demographics with enthesis stiffness and intra and inter -observer agreements using shear wave elastography (SWE).

Methods: 98 healthy volunteers were recruited. SWE was performed on quadriceps, suprapatellar, infrapatellar, and Achilles entheses.

View Article and Find Full Text PDF

Background: Isolated fractures of the greater tuberosity represent up to 20% of all proximal humeral fractures. Conservative and surgical treatment strategies are reported. Fracture displacement on radiographs is a key factor in treatment decisions, but the accuracy of measurement methods can limit this process.

View Article and Find Full Text PDF

Objectives: The enormous burden that cardiovascular diseases put on individuals and societies warrants reliable biomarkers of disease risk to optimize disease prevention. We studied longitudinal movement (LMov) in arterial walls using ultrasound of the common carotid artery (CCA). We believe that LMov could be a sensitive biomarker of cardiovascular health and in this study, we evaluate the intra-observer repeatability and inter-observer precision of our method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!