ENHANCED RADIOACTIVE CONTENT OF 'BALANCE' BRACELETS.

Radiat Prot Dosimetry

Nuclear Research Centre Negev, P.O. Box 9001, Beer Sheva 84190, Israel.

Published: September 2016

During a routine whole body counting measurement of a worker at the Nuclear Research Center Negev, abnormal activities of (232)Th and (238)U were measured. After a thorough investigation, it was found that the radioactivity was due to a rubber bracelet ('balance bracelet') worn by the worker during the measurement. The bracelet was counted directly by an high pure germanium gamma spectrometry system, and the specific activities determined were 10.80 ± 1.37 Bq g(-1) for (232)Th and 5.68 ± 0.88 Bq g(-1) for natural uranium. These values are obviously high compared with normally occurring radioactive material (NORM) average values. The dose rate to the wrist surface was estimated to be ∼3.9 µGy h(-1) and ∼34 mGy for a whole year. The dose rate at the centre of the wrist was estimated to be ∼2.4 µGy h(-1) and ∼21 mGy for a whole year. The present findings stresses a more general issue, as synthetic rubber and silicone products are common and widely used, but their radioactivity content is mostly uncontrolled, thus causing unjustified exposure due to enhanced NORM radioactivity levels.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncv456DOI Listing

Publication Analysis

Top Keywords

dose rate
8
µgy h-1
8
mgy year
8
enhanced radioactive
4
radioactive content
4
content 'balance'
4
'balance' bracelets
4
bracelets routine
4
routine body
4
body counting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!