We report the five-year outcome of a randomised controlled trial which used radiostereometric analysis (RSA) to assess the influence of surface oxidised zirconium (OxZr, Oxinium) on polyethylene wear in vivo. A total of 120 patients, 85 women and 35 men with a mean age of 70 years (59 to 80) who were scheduled for primary cemented total hip arthroplasty were randomly allocated to four study groups. Patients were blinded to their group assignment and received either a conventional polyethylene (CPE) or a highly cross-linked (HXL) acetabular component of identical design. On the femoral side patients received a 28 mm head made of either cobalt-chromium (CoCr) or OxZr. The proximal head penetration (wear) was measured with repeated RSA examinations over five years. Clinical outcome was measured using the Harris hip score. There was no difference in polyethylene wear between the two head materials when used with either of the two types of acetabular component (p = 0.3 to 0.6). When comparing the two types of polyethylene there was a significant difference in favour of HXLPE, regardless of the head material used (p < 0.001). In conclusion, we found no advantage of OxZr over CoCr in terms of polyethylene wear after five years of follow-up. Our findings do not support laboratory results which have shown a reduced rate of wear with OxZr. They do however add to the evidence on the better resistance to wear of HXLPE over CPE.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1302/0301-620X.97B11.36137 | DOI Listing |
J Orthop Surg Res
January 2025
Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, Shandong, P.R. China.
Background: Vitamin E-diffused highly cross-linked polyethylene (HXLPE/Vit E) is a relatively advanced material used in total hip arthroplasty (THA) but whether it shows superiority is unclear.
Objective: This meta-analysis was performed to investigate the effect of HXLPE/Vit E liners in THA.
Methods: Medline/PubMed, Embase and Cochrane Library databases were searched to retrieve studies assessing the efficacy of HXLPE/Vit E liners in THA with the design of a randomized, controlled trial.
Environ Res
January 2025
Southern California Coastal Water Research Project, Costa Mesa, CA, 92626, United States.
The concentration, character, and distribution of microplastics in coastal marine environments remain poorly understood, with most research focusing on the abundance of microplastics at the sea surface. To address this gap, we conducted one of the first comprehensive assessments of microplastic distribution through the marine water column and benthic sediment during the wet and dry season in the coastal waters of the San Pedro Bay Southern California, USA. Microplastic concentrations in the water column did not vary significantly across season but were significantly higher in nearshore environments and at the surface of the water column.
View Article and Find Full Text PDFArthroplast Today
December 2024
Hospital Pavia Arecibo, Arecibo Orthopedic Institute, Arecibo, PR, USA.
Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure.
View Article and Find Full Text PDFSurg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFCureus
December 2024
Medical Affairs, Dr. Reddy's Laboratories Ltd., Hyderabad, IND.
Background Toothbrush manufacturers commonly use bristle materials such as nylon, polybutylene terephthalate, polypropylene, polyethylene terephthalate, boar hair, bamboo, carbon fiber, silicone, polylactic acid, or their modifications such as Curen. Nylon filaments have long been demonstrated to be durable and are widely used, but not much is known regarding the performance of Curen filaments compared to nylon filaments. This in vitro study compared the stiffness, abrasion potential, abrasion resistance, and bristle surface changes of Curen and nylon filaments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!