The quality management (QM) of POCT summarizes its internal quality control (IQC) and external quality assessment (EQA). For QM requirements in POCT, ISO 22870-Point-of-care testing (POCT) -Requirements for quality and competence and ISO 15189-Medical laboratories-Requirements for quality and competence, it is performed under the guidance of the QM committee. The role of the POC coordinator and/or medical technologist of the clinical laboratory is important. On measurement performance of POCT devices, it is necessary to confirm data on measurement performance from the manufacturer other than those in the inserted document. In the IQC program, the checking and control of measurement performance are the targets. On measurements of QC samples by the manufacturer, it is essential to check the function of devices. In addition, regarding the EQA program, in 2 neighboring facilities, there is an effect to confirm the current status of measurement and commutability assessment in these laboratories using whole blood along with residual blood samples from daily examinations in the clinical laboratory.

Download full-text PDF

Source

Publication Analysis

Top Keywords

measurement performance
12
quality control
8
external quality
8
quality assessment
8
quality competence
8
clinical laboratory
8
quality
6
[internal quality
4
control external
4
assessment poct]
4

Similar Publications

A comprehensive benchmarking for evaluating TCR embeddings in modeling TCR-epitope interactions.

Brief Bioinform

November 2024

Department of Computer Science, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon Tong, Hong Kong, 999077, China.

The complexity of T cell receptor (TCR) sequences, particularly within the complementarity-determining region 3 (CDR3), requires efficient embedding methods for applying machine learning to immunology. While various TCR CDR3 embedding strategies have been proposed, the absence of their systematic evaluations created perplexity in the community. Here, we extracted CDR3 embedding models from 19 existing methods and benchmarked these models with four curated datasets by accessing their impact on the performance of TCR downstream tasks, including TCR-epitope binding affinity prediction, epitope-specific TCR identification, TCR clustering, and visualization analysis.

View Article and Find Full Text PDF

Background: Nasal high flow (NHF) has been proposed to sustain high intensity exercise in people with COPD, but we have a poor understanding of its physiological effects in this clinical setting.

Research Question: What is the effect of NHF during exercise on dynamic respiratory muscle function and activation, cardiorespiratory parameters, endurance capacity, dyspnoea and leg fatigue as compared to control intervention.

Study Design And Methods: Randomized single-blind crossover trial including COPD patients.

View Article and Find Full Text PDF

Importance: An accurate noninvasive biomarker test is needed for the early diagnosis of bladder cancer.

Objective: To evaluate the performance of a urinary DNA methylation test (PENK methylation) and compare its diagnostic accuracy with that of the nuclear matrix protein 22 (NMP22) test or urine cytology test.

Design, Setting, And Participants: In this prospective multicenter study at 10 sites in the Republic of Korea, individuals 40 years and older with hematuria undergoing cystoscopy within 3 months between March 11, 2022, and May 30, 2024, participated.

View Article and Find Full Text PDF

Importance: Rising prescription medication costs under Medicaid have led to increased procedural prescription denials by health plans. The effect of unresolved denials on chronic condition exacerbation and subsequent acute care utilization remains unclear.

Objective: To examine whether procedural prescription denials are associated with increased net spending through downstream acute care utilization among Medicaid patients not obtaining prescribed medication following a denial.

View Article and Find Full Text PDF

Atomic force microscopy (AFM) has reached a significant level of maturity in biology, demonstrated by the diversity of modes for obtaining not only topographical images but also insightful mechanical and adhesion data by performing force measurements on delicate samples with a controlled environment (e.g., liquid, temperature, pH).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!