A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Unreliable Tracking Ability of the Third-Generation FloTrac/Vigileo™ System for Changes in Stroke Volume after Fluid Administration in Patients with High Systemic Vascular Resistance during Laparoscopic Surgery. | LitMetric

Background: The FloTrac/Vigileo™ system does not thoroughly reflect variable arterial tones, due to a lack of external calibration. The ability of this system to measure stroke volume and track its changes after fluid administration has not been fully evaluated in patients with the high systemic vascular resistance that can develop during laparoscopic surgery.

Methods: In 42 patients undergoing laparoscopic prostatectomy, the stroke volume derived by the third-generation FloTrac/Vigileo™ system (SV-Vigileo), the stroke volume measured using transesophageal echocardiography (SV-TEE) as a reference method, and total systemic vascular resistance were evaluated before and after 500 ml fluid administration during pneumoperitoneum combined with the Trendelenburg position.

Results: Total systemic vascular resistance was 2159.4 ± 523.5 dyn·s/cm5 before fluid administration. The SV-Vigileo was significantly higher than the SV-TEE both before (68.8 ± 15.9 vs. 57.0 ± 11.0 ml, P < 0.001) and after (73.0 ± 14.8 vs. 64.9 ± 12.2 ml, P = 0.003) fluid administration. During pneumoperitoneum combined with the Trendelenburg position, Bland-Altman analysis for repeated measures showed a 53.8% of percentage error between the SV-Vigileo and the SV-TEE. Four-quadrant plot (69.2% of a concordance rate) and polar plot analysis (20.6° of a mean polar angle, 16.4° of the SD of a polar angle, and ±51.5° of a radial sector containing 95% of the data points) did not indicate a good trending ability of the FloTrac/Vigileo™ system.

Conclusions: The third-generation FloTrac/Vigileo™ system may not be useful in patients undergoing laparoscopic surgery, based on unreliable performance in measuring the stroke volume and in tracking changes in the stroke volume after fluid administration during pneumoperitoneum combined with the Trendelenburg position.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4631474PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0142125PLOS

Publication Analysis

Top Keywords

stroke volume
24
fluid administration
24
flotrac/vigileo™ system
16
systemic vascular
16
vascular resistance
16
third-generation flotrac/vigileo™
12
administration pneumoperitoneum
12
pneumoperitoneum combined
12
combined trendelenburg
12
changes stroke
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!