Quantitative SPECT in radiation dosimetry.

Semin Nucl Med

Division of Nuclear Medicine, New York Hospital-Cornell Medical Center, NY 10021.

Published: January 1989

Accurate and precise radiation dosimetry is critical for the successful therapeutic application of systemically administered radionuclides, including, of course, radionuclides in the form of radiolabeled antibody. This requires determination, based on discrete serial measurements, of the time-dependent concentrations and/or total amounts of radioactivity in situ in order to calculate source region cumulated activities. Based on extensive studies (with clinically realistic numbers of counts and accuracies of the order of 10%) in simple geometric phantoms, in complex anthropomorphic phantoms, in animal models, and in humans, quantitative rotating scintillation camera-based single-photon emission computed tomography (SPECT) now appears to be a practical approach to such measurements. The basis of the quantitative imaging capability of a three-dimensional imaging modality such as SPECT is the elimination in the reconstructed image of counts emanating from activity surrounding the source region. Subject to considerations such as the reconstruction algorithm, attenuation and scatter corrections, and, most importantly, statistical uncertainty, the counts in a pixel in a reconstructed image are therefore directly proportional to the actual counts emanating from the corresponding voxel in situ. Among intrinsic, pre-processing, and post-processing attenuation corrections, post-processing algorithms, the most widely used approach in current commercial SPECT systems, have proven adequate in uniformly attenuating parts of the body (eg, abdomen, pelvis), subject to accurate delineation of the body contour. Although a number of sophisticated scatter correction methods have been developed, the lack of explicit scatter correction has, in practice, not been a major impediment to reasonably accurate quantitative SPECT imaging, despite scattered radiation representing up to 50% of the counts in a large source region (eg, liver). Because of its mathematical propagation in the image reconstruction process, statistical uncertainty (ie, "noise") in SPECT is far greater than would be expected if it were distributed according to Poisson statistics, as in planar imaging. The low "single slice" sensitivity of rotating scintillation camera-based SPECT is therefore the principal limitation of practical quantitative SPECT. Accordingly, absolute quantitation of count-limited clinical images has been accomplished using a judiciously selected "non-ramp" filter function. In summary, reasonable quantitative SPECT imaging is now feasible clinically, even without sophisticated scatter corrections, at least in uniformly attenuating parts of the body.(ABSTRACT TRUNCATED AT 400 WORDS)

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0001-2998(89)80035-2DOI Listing

Publication Analysis

Top Keywords

quantitative spect
16
source region
12
radiation dosimetry
8
rotating scintillation
8
scintillation camera-based
8
spect
8
reconstructed image
8
counts emanating
8
scatter corrections
8
statistical uncertainty
8

Similar Publications

This 2025 updated consensus outlines the diagnostic strategy for transthyretin amyloid cardiomyopathy (ATTR-CM). Given that ATTR-CM is a significant contributor to heart failure, this article emphasizes the importance of making an early and precise diagnosis, particularly as new therapeutic options become available. Highlighting the critical importance of an early and accurate diagnosis, particularly in light of emerging therapeutic modalities, this consensus underscores the central role of Tc-pyrophosphate (PYP) scintigraphy as a non-invasive diagnostic tool.

View Article and Find Full Text PDF

Nuclear Cardiology Surrogate Biomarkers in Clinical Trials.

J Nucl Med

January 2025

Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California;

Nuclear cardiology offers a diverse range of imaging tools that provide valuable insights into myocardial perfusion, inflammation, metabolism, neuroregulation, thrombosis, and microcalcification. These techniques are crucial not only for diagnosing and managing cardiovascular conditions but also for gaining pathophysiologic insights. Surrogate biomarkers in nuclear cardiology, represented by detectable imaging changes, correlate with disease processes or therapeutic responses and can serve as endpoints in clinical trials when they demonstrate a clear link with these processes.

View Article and Find Full Text PDF
Article Synopsis
  • This study examined the effectiveness of bone SPECT imaging with and without SwiftScan technology in patients with prostate cancer bone metastases.
  • Involving 10 patients and 130 metastatic lesions, the research compared the quality of images produced at various acquisition times, showcasing improved quality scores and correlation coefficients with SwiftScan.
  • Findings indicated that SwiftScan allowed for a 50% reduction in acquisition time while still maintaining acceptable image quality and accurate quantitative measurements like SUV and contrast-to-noise ratios.
View Article and Find Full Text PDF

Usefulness of dynamic perfusion SPECT with quantitative assessment of myocardial perfusion reserve for the detection of myocardial ischaemia in patients with presumed new left bundle branch block.

Eur Heart J Imaging Methods Pract

July 2024

Department of Nuclear Medicine, CHU de Caen Normandie, Normandie Univ, UNICAEN UR  4650 PSIR, Avenue Cote de Nacre, 14000 Caen, France.

Article Synopsis
  • The study aimed to assess how well dynamic SPECT with quantitative analysis of myocardial blood flow (MBF) and myocardial flow reserve (MFR) can detect coronary artery disease (CAD) in patients with new left bundle branch block (LBBB).
  • The evaluation involved 174 patients with LBBB, finding SPECT abnormalities in only a small percentage, and highlighting a correlation between reduced MFR and fixed defects, although only a few patients had significant CAD after further examination.
  • The conclusion suggests that routine screening for CAD in patients with presumed new LBBB may not be necessary, given the low incidence of actual CAD found.
View Article and Find Full Text PDF

Recent developments in translational imaging of in vivo gene therapy outcomes.

Mol Ther

December 2024

Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California, Los Angeles, California 90095; Crump Institute for Molecular Imaging, University of California, Los Angeles, Los Angeles, California 90095; Jonsson Comprehensive Cancer Center, University of California, Los Angeles, Los Angeles, California 90095. Electronic address:

Gene therapy achieves therapeutic benefits by delivering genetic materials, packaged within a delivery vehicle, to target cells with defective genes. This approach has shown promise in treating various conditions, including cancer, metabolic disorders, and tissue degenerative diseases. Over the past five years, molecular imaging has increasingly supported gene therapy development in both preclinical and clinical studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!