A practical quantitative single photon emission computed tomographic (SPECT) technique based on an empirical threshold analysis permits accurate measurements in humans of drug delivery and absorbed radiation dose. The limits of the method have been explored using a wide range of phantom volumes, concentrations, and target-to-nontarget ratios. A threshold of 43% was found to give the best results using volumes of 30 to 3,800 cc. An excellent correlation (r = .99 with a standard error of estimate [SEE] of 41 cc) was found between SPECT measured volumes and actual phantom volumes. A similarly high correlation (r = .98, SEE = 260 counts/voxel) was found in 77 measurements of concentrations between 0.01 and 3.6 microCi/cc. There was a direct relationship between the target-to-nontarget ratio of phantoms and the accuracy of volume measurements. The technique has been validated by an excellent in vivo/in vitro correlation of uptake in human tumors. The tumor cumulative concentration and tumor-to-blood ratio were used for assessment of drug delivery. In vivo quantitative measurements of the pharmacokinetics of technetium-99m (99mTc) glucoheptonate, cobalt-57 (57Co) bleomycin and platinum-195m (195mPt) cisplatin in human tumors in vivo indicates that, in contrast with tumor models in animals, there is a marked variability in drug delivery even in tumors with the same histology. Future development of labeled drugs should make it possible to use quantitative SPECT for predicting tumor response to therapy and for tailoring chemotherapy for the individual patient under treatment. SPECT quantitation of organ concentration was used for Medical Internal Radiation Dose committee (MIRD) calculations of organ absorbed radiation dose from 99mTc-labeled RBCs. Excellent in vivo/in vitro correlations were obtained between SPECT measured concentrations of blood radioactivity in the heart and in vitro measurements of blood samples. The possibilities and limitations of this technique are discussed and its use for in vivo measurement in humans of absorbed radiation dose from radiopharmaceuticals is suggested.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0001-2998(89)80034-0DOI Listing

Publication Analysis

Top Keywords

radiation dose
20
drug delivery
16
absorbed radiation
16
human tumors
12
spect technique
8
organ absorbed
8
phantom volumes
8
spect measured
8
excellent vivo/in
8
vivo/in vitro
8

Similar Publications

Objective: The purpose of this study was to present a newly designed 3D-printed personalized model (3D PPM) of a radiofrequency needle guide with a maxillary fixation for gasserian ganglion (GG) puncture.

Methods: Implementation of 3D CT-guided radiofrequency therapy of the GG with and without use of 3D PPM was analyzed. The following parameters were assessed: radiation time, dose area product, air kerma reference point, pain severity during the puncture needle insertion, prosopalgia regression degree (according to visual analog scale) and the severity of facial numbness (according to the Barrow Neurological Institute scale) in the early postoperative period, and postpuncture complications.

View Article and Find Full Text PDF

Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.

View Article and Find Full Text PDF

Recent investigations into radiation-induced side effects have focused on understanding the physiopathological consequences of irradiation on late-responding tissues like the spinal cord, which can lead to chronic progressive myelopathy. Proton therapy, an advanced radiation treatment, aims to minimize damage to healthy tissues through precise dose deposition. However, challenges remain, particularly regarding the variation in dose distribution, characterized by maximum deposition at the end of the proton range, known as the distal fall-off of a spread-out Bragg peak.

View Article and Find Full Text PDF

An activity concentration-based proposal for radon management in workplaces involving NORM in Canada.

Radiat Environ Biophys

December 2024

Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa, ON, K1A 1C1, Canada.

The Canadian Guidelines for the Management of Naturally Occurring Radioactive Materials (NORM) have been developed to manage radiation doses received in workplaces involving NORM, such as mineral extraction and processing, oil and gas production, metal recycling or water treatment facilities. This management strategy works well for most naturally occurring radioactive materials in workplaces, with the exception of radon. Radon is a naturally occurring radioactive gas generated by the decay of uranium-bearing minerals in rocks and soils.

View Article and Find Full Text PDF

Biomarker-Directed Radiotherapy in Breast Cancer: A Narrative Review.

JAMA Oncol

January 2025

Department of Radiation Oncology, Iridium Netwerk, Wilrijk-Antwerp, Belgium.

Importance: Integration of molecular biomarker information into systemic therapy has become standard practice in breast cancer care. However, its implementation in guiding radiotherapy (RT) is slower. Although postoperative RT is recommended for most patients after breast-conserving surgery and, depending on risk factors, following mastectomy, emerging evidence has indicated that patients with low scores on gene expression signatures or selected clinical-pathological features may have very low local recurrence rates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!