How to perform low-dose computed tomography for renal colic in clinical practice.

Diagn Interv Imaging

Department of medical imaging, HIA Legouest, 57077 Metz, France.

Published: April 2016

Computed tomography (CT) has become the reference technique in medical imaging for renal colic, to diagnose, plan treatment and explore differential diagnosis. Its main limitation is the radiation dose, especially as urinary stone disease tends to relapse and mainly affects young people. It is therefore essential to reduce the CT radiation dose when renal colic is suspected. The goal of this review was twofold. First, we wanted to show how to use low-dose CT in patients with suspected renal colic in current clinical practice. Second, we wished to discuss the different ways of reducing CT radiation dose by considering both behavioral and technological factors. Among the behavioral factors, limiting the scan coverage area is a straightforward and effective way to reduce the dose. Improvement of technological factors relies mainly on using automatic tube current modulation, lowering the tube voltage and current as well using iterative reconstruction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diii.2015.05.013DOI Listing

Publication Analysis

Top Keywords

renal colic
16
radiation dose
12
computed tomography
8
clinical practice
8
technological factors
8
perform low-dose
4
low-dose computed
4
renal
4
tomography renal
4
colic
4

Similar Publications

Adrenal incidentalomas are increasingly identified through advanced imaging, posing diagnostic challenges due to their varied benign and malignant nature. We present the case of a 29-year-old male who, during evaluation for left renal colic, was found to have a 5.5 cm heterogeneous right adrenal mass on non-contrast CT, initially suggestive of a myelolipoma.

View Article and Find Full Text PDF

Kidney stones typically present as renal colic in emergency departments (EDs), where patients experience severe pain and often require parenteral therapy for symptom management. The economic burden associated with managing kidney stones exceeds USD 5 billion annually in the US and accounts for more than a million visits to EDs each year. There is clear evidence emphasizing the need for innovative and alternative pain control options for patients with renal colic.

View Article and Find Full Text PDF

Purpose: To examine the safety and efficiency of a single-drug therapy with silodosin or tamsulosin versus combined therapy with silodosin plus tadalafil and tamsulosin plus tadalafil as a medical expulsive therapy (MET) for lower ureteral stones.

Methods: This research was a prospective randomized clinical trial carried out at Fayoum University Hospital, Egypt, over one year. Patients with lower ureteral stones (5-10 mm) were randomly allocated into one of four treatment groups.

View Article and Find Full Text PDF

Background: The ongoing opioid epidemic in the United States has reinforced the need to provide multimodal and non-opioid pain management interventions. The PAMI-ED ALT program employed a multifaceted approach in the Emergency Department (ED) developing electronic health record (EHR) pain management order panels and discharge panels, as well as educating patients, clinicians, and ED staff on opioid alternatives, including non-pharmacologic interventions. The primary objective of this analysis was to compare changes in opioid and non-opioid analgesic administrations and prescribing in ED patients with select pain conditions (renal colic, headache, low back, and non-low back musculoskeletal pain) before and after implementation of PAMI ED-ALT.

View Article and Find Full Text PDF

Optimizing Scan Range in Computed Tomography of Kidneys, Ureters, and Bladder: A Retrospective Study on Reducing Overscanning.

Medicina (Kaunas)

November 2024

Radiological Sciences Department, College of Applied Medical Sciences, King Saud University, P.O. Box 145111, Riyadh 4545, Saudi Arabia.

: Computed tomography of the kidneys, ureters, and bladder (CT KUB) is essential for evaluating urinary stones but also exposes patients to significant radiation. The scanning field should be minimized to only the necessary area to limit this radiation exposure. This study aims to assess the extent of CT KUB overscanning in renal colic procedures and identify the appropriate vertebral level for starting CT KUB scans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!