Using a thin B-scan probe the anterior chamber angle was ultrasonographically studied using a contact eye cup filled with saline. The width of the chamber angle was measured on the display video copy and compared with the gonioscopic findings. Sixty-four eyes with primary glaucoma and 53 nonglaucomatous eyes were examined. In eyes with gonioscopic narrow angle the real ultrasonographic width of the chamber angle was varied considerably from case to case. In eyes where the chamber angle was not visible by gonioscopy it was not always closed. The correlation between the width of the angle and the depth of the anterior chamber was weak. There was often a plateau iris, which was demonstrated clearly by B-scan ultrasonography.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2008-1046326DOI Listing

Publication Analysis

Top Keywords

chamber angle
20
anterior chamber
12
width chamber
8
angle
7
chamber
6
[comparative studies
4
width
4
studies width
4
width anterior
4
angle echography
4

Similar Publications

Differences in Ocular Biometry Between Short-Axial and Normal-Axial Eyes in the Elderly Japanese.

Clin Ophthalmol

January 2025

Department of Ophthalmology, Saitama Medical Center, Saitama Medical University, Kawagoe-shi, Saitama, Japan.

Purpose: Among patients with angle-closure glaucoma, it is common to have a short-axial eye, which also makes it difficult to select an appropriate intraocular lens. Previous studies have focused on the ocular biometry of the long-axial eye, whereas only a few reports have focused on the short-axial eye. This study aimed to clarify the characteristics of the short-axial eye on ocular biometry among the elderly Japanese.

View Article and Find Full Text PDF

Can fundus features tell us something about 3D eye shape?

Ophthalmic Physiol Opt

January 2025

Robert O Curle Ophthalmology Suite, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, UK.

Purpose: To determine whether imaging features derived from fundus photographs contain 3D eye shape information beyond that available from spherical equivalent refraction (SER).

Methods: We analysed 99 eyes of 68 normal adults in the UK Biobank. An ellipsoid was fitted to the entire volume of each posterior eye (vitreous chamber without the lens)-segmented from magnetic resonance imaging of the brain.

View Article and Find Full Text PDF

Purpose: To characterize the anterior segment (AS) morphology of patients with long-term silicone oil (SiO) in situ (> 12 months) following pars plana vitrectomy (PPV).

Methods: This prospective, comparative characterization study was conducted between January 2022 and July 2023. Patients were included and sorted based on if they had undergone PPV without long-term SiO or had SiO in situ for at least 12 months at the time of review and image collection.

View Article and Find Full Text PDF

Lattice Boltzmann Modeling of Additive Manufacturing of Functionally Graded Materials.

Entropy (Basel)

December 2024

AGH University of Krakow, Faculty of Metals Engineering and Industrial Computer Science, al. Mickiewicza 30, 30-059 Kraków, Poland.

Functionally graded materials (FGMs) show continuous variations in properties and offer unique multifunctional capabilities. This study presents a simulation of the powder bed fusion (PBF) process for FGM fabrication using a combination of Unity-based deposition and lattice Boltzmann method (LBM)-based process models. The study introduces a diffusion model that allows for the simulation of material mixtures, in particular AISI 316L austenitic steel and 18Ni maraging 300 martensitic steel.

View Article and Find Full Text PDF

Purpose: To compare changes in angle morphology, anterior chamber depth (ACD) and refractive prediction error (PE) after phacoemulsification between pseudoexfoliative (PEX) and non-PEX eyes.

Methods: Prospective case-control study of eyes submitted to cataract surgery. Biometric data and angle parameters - Anterior Chamber Angle (ACA), Angle Opening Distance (AOD), Scleral Spur Angles (SSA) and Trabecular Iris Space Area (TISA) - were measured preoperatively and 1-month postoperatively through swept-source anterior segment optical coherence tomography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!