Duplex Doppler sonography of renal transplants. Correlation with histopathology.

J Ultrasound Med

Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232.

Published: February 1989

The correlation of histopathologic findings with duplex Doppler sonography (DDS) in 24 biopsies in 21 patients was studied. The resistive indices (RI) of the acute rejection group were statistically different (p = .04) from those that were negative for rejection or clinical controls. Although the number of cases of moderate to severe interstitial and/or vascular rejection was relatively small compared to the mild group, patients with the more severe forms of rejection (moderate to severe interstitial with or without vascular rejection) tended to have higher RIs (.89 +/- .04) than those with the milder forms of rejection (.75 +/- .05).

Download full-text PDF

Source
http://dx.doi.org/10.7863/jum.1989.8.2.89DOI Listing

Publication Analysis

Top Keywords

duplex doppler
8
doppler sonography
8
moderate severe
8
severe interstitial
8
vascular rejection
8
forms rejection
8
rejection
6
sonography renal
4
renal transplants
4
transplants correlation
4

Similar Publications