Target-Controlled Infusion: A Mature Technology.

Anesth Analg

From the *Department of Anesthesiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands; †Glen Pharma, Knutsford, Cheshire, United Kingdom; ‡Department of Anesthesiology, Intensive Care, Rescue and Pain Medicine, Kantonsspital St. Gallen, St. Gallen, Switzerland; §Faculty of Medicine, Anesthesiology, University of Berne, Berne, Switzerland; and ∥Department of Anesthesia, Ghent University, Gent, Belgium.

Published: January 2016

Target-controlled infusions (TCIs) have been used in research and clinical practice for >2 decades. Nonapproved TCI software systems have been used during the conduct of almost 600 peer-reviewed published studies involving large numbers of patients. The first-generation pumps were first approved in 1996, and since then an estimated 25,000 units have been sold and used. Second-generation pumps were first approved in 2003. During 2004 to 2013, >36,000 units were sold. Currently, TCI systems are approved or available in at least 96 countries. TCI systems are used to administer propofol and opioids for IV sedation and general anesthesia for millions of patients every year. In countries where TCI systems are approved, nonapproved software is still commonly used in studies of the pharmacology of hypnotics and opioids, because research software offers greater flexibility than approved TCI systems. Research software is also readily integrated into data management modules. Although TCI is a part of established practice around the world, TCI devices have not received regulatory approval in the United States. In the United States, TCI administration of propofol and opioids for sedation and anesthesia is only possible using research software in IRB-approved research studies.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0000000000001009DOI Listing

Publication Analysis

Top Keywords

tci systems
16
tci
8
pumps approved
8
units sold
8
systems approved
8
countries tci
8
propofol opioids
8
opioids sedation
8
united states
8
software
5

Similar Publications

Technical and management coaching for government institutions: Lessons learned and health systems transformations across 8 countries in sub-Saharan Africa and India.

PLOS Glob Public Health

January 2025

Department of Population, William H. Gates Sr. Institute for Population and Reproductive Health, Family and Reproductive Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, United States of America.

Traditional engagement with local governments often relies on financial and human resources from international or local partners, leading to direct implementation by organizations, which can hinder sustainability. While some organizations include sustainability indicators, few focus on transferring technical and financial ownership to governments. The Challenge Initiative (TCI) uses a phased coaching model-lead, assist, observe, and monitor-to build local government capacity for scaling family planning (FP) and adolescent and youth sexual and reproductive health (AYSRH) programs.

View Article and Find Full Text PDF

Importance: The closed-loop infusion system can automatically adjust and maintain the depth of anesthesia by using the propofol target-controlled infusion (TCI) model under the feedback guidance of the bispectral index (BIS).

Objective: To evaluate the safety and superiority of closed-loop TCI of propofol guided by BIS during maintenance of generalized intravenous anesthesia for preschool children.

Methods: A total of 120 children aged 1-6 years were enrolled and were divided into a closed-loop feedback group (Group C) and an open-loop manual control group (Group O), with 60 participants in each group.

View Article and Find Full Text PDF

Heavy-legged robots (HLRs), integral to optimizing efficiency in manufacturing and transportation, rely on advanced active servo fault diagnosis and fault-tolerant control (FTC) mechanisms. This study presents an FTC framework with active fault status identification, fault tolerance capability assessment, and model uncertainty handling. A key contribution is the introduction of an active servo fault state estimator (ASFSE), which enables real-time monitoring of servo status by comparing residual differences between servo and controller outputs.

View Article and Find Full Text PDF

To explore the method of obtaining the key parameters of the average value articulator in healthy people based on mandibular movement trajectory data, with a view to providing a reference for the clinical application of the average value articulator. One hundred healthy volunteers (42 males and 58 females) with individual normal occlusion, aged 18-55 years old, who met the inclusion criteria were recruited from Beijing, and their mandibular movement trajectory data were collected. The left and right sagittal condylar inclination(SCI) and transversal condylar inclination(TCI) were obtained from the values of the articulator parameters which were generated in the mandibular movement analysis system.

View Article and Find Full Text PDF

Background: Piauí is located in Northeastern Brazil, an endemic area for Chagas disease, with the Brazilian semiarid representing the second region in number of people infected by the parasite Trypanosoma cruzi. The state of Piauí is one of the most socially vulnerable territories with direct impact on the access to diagnosis and treatment of Chagas disease for the population living in rural communities. Triatoma brasiliensis is the vector species of greatest epidemiological importance in Northeastern Brazil.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!