Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Diameters of coronary artery aneurysms (CAAs) complicating acute phase KD can strongly predict the long-term prognosis of coronary artery lesions (CAL). Recently, computed tomographic angiography (CTA) has been used to detect CAL, and the purpose of this study was to determine whether coronary artery diameters measurements by CTA using dual-source computed tomography (DSCT) can be used instead of coronary angiogram (CAG) measurements. Twenty-five patients (22 males and three females) with CAL due to KD, who had undergone both CTA and CAG within one year, were retrospectively evaluated between 2007 and 2013. A prospective electrocardiogram-triggered CTA was performed on a DSCT (SOMATOM(®) Definition, Siemens Healthcare, Germany). Two pediatric cardiologists independently measured the diameters of CAAs twice in each maximum intensity projection (MIP), curved multiplaner reconstruction (MPR) and CAG. We measured 161 segments in total (segment 1-3, 5-7, 11, 13). Diagnostic accuracy was expressed as κ coefficient. A Bland-Altman analysis was also used to assess the intra-observer, inter-observer and inter-modality agreement. The diagnostic quality of CTA was excellent (κ = 0.93). Excellent inter-observer agreement for the diameters of CAAs was obtained for MIP, MPR and CAG and for the intra-observer agreement. The inter-modality agreement was also excellent in measurements of CAA (MPR-CAG: y = 0.9x + 0.40, r = 0.97, p < 0.0001 MIP-CAG: y = x + 0.1, r = 0.94, p < 0.0001). These values in normal coronary arteries were also obtained. We found a significant correlation between CTA and CAG in measuring the coronary arteries. We conclude that measuring coronary artery diameters by CTA is reliable and useful.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00246-015-1297-z | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!