Purpose: There are few previous reports on maximal pelvic lymph node sizes and no data on normal mesorectal nodes. Therefore, the aim of the study was to estimate the normal size of pelvic lymph nodes and to determine the upper limits of the normal range.

Materials And Methods: Pelvic magnetic resonance imaging (MRI) examinations were prospectively carried out using a Intera 1.5 T magnet (Philips, the Netherlands), on 36 healthy volunteers (22 females, 14 males, mean age 25 years). A balanced fast field echo (b-FFE) sequence was used with the following parameters: 3-mm-thick contiguous slice, matrix 512 × 512. Short axis diameters of pelvic and inguinal lymph nodes were measured in each anatomic territory (internal iliac, external iliac, common iliac, mesorectum and inguinal). After normalization of the measurements, the influences of age, gender, laterality and territory were evaluated. Upper limits (95th percentile) were then calculated.

Results: A total of 1147 lymph nodes were measured. Age, gender and side (right/left) had no significant influence on size. The upper limits of the normal range were, respectively, 5.3, 4.4, 6.3 and 3.9 mm for the external and common iliac, internal iliac, inguinal and mesorectum nodes.

Conclusion: This work presents maximal normal values for each pelvic area, and the values for mesorectum nodes are reported for the first time.

Advances In Knowledge: The mesorectum nodes should be considered as abnormal when they are over 4 mm in short diameter. For the other node areas, the upper limits of the normal range were, respectively, 6, 6, 5, 7 mm for the external and common iliac, internal, iliac and inguinal nodes for the short axis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00276-015-1581-xDOI Listing

Publication Analysis

Top Keywords

upper limits
16
pelvic lymph
12
lymph nodes
12
limits normal
12
internal iliac
12
common iliac
12
lymph node
8
normal
8
mri examinations
8
short axis
8

Similar Publications

This study evaluates the measurement accuracy of the Hanvon FY730 upper-arm blood pressure (BP) monitor, which uses the Korotkoff sound method, in compliance with the AAMI/ESH/ISO universal standard (ISO 81060-2:2018). A clinical trial involving 86 eligible adults was conducted, and data were analyzed based on standardized protocols. The mean differences between the device and reference measurements for systolic blood pressure (SBP) and diastolic blood pressure (DBP) were -0.

View Article and Find Full Text PDF

Embryogenesis is remarkably robust to temperature variability, yet there is limited understanding of the homeostatic mechanisms that offset thermal effects during early development. Here, we measured the thermal acclimation response of upper thermal limits and profiled chromatin state and the transcriptome of embryos (Bownes Stage 11) using single-nuclei multiome ATAC and RNA sequencing. We report that thermal acclimation, while preserving a common set of primordial cell types, rapidly shifted the upper thermal limit.

View Article and Find Full Text PDF

Background & Aims: Biliary abnormalities in autoimmune hepatitis (AIH) and interface hepatitis in primary biliary cholangitis (PBC) occur frequently, and misinterpretation may lead to therapeutic mistakes with a negative impact on patients. This study investigates the use of a deep learning (DL)-based pipeline for the diagnosis of AIH and PBC to aid differential diagnosis.

Methods: We conducted a multicenter study across six European referral centers, and built a library of digitized liver biopsy slides dating from 1997 to 2023.

View Article and Find Full Text PDF

Background: The use of advanced diagnostic methods, such as high-resolution CT or PET-CT scans, are limited in low and middle-income countries (LMICs). In gastric cancer, occult peritoneal disease may be present in up to 20% of cases, limiting the benefits of surgical resection. Accurate staging of gastric cancer is essential to ensure optimal patient management and prevent undue morbidity from unnecessary surgery.

View Article and Find Full Text PDF

To evaluate the bioequivalence and safety of oral rivaroxaban tablets between a test formulation and a reference formulation in healthy Chinese subjects, a randomized, open, 2-formulation, 4-cycle, complete repeat crossover study was conducted under both fasting and fed states. Thirty-six healthy participants were enrolled separately for the fasting and fed groups, and each subject received a single oral dose of 20 mg of the test or reference formulation of rivaroxaban tablets per cycle. Blood samples were collected at specified intervals, and rivaroxaban was analyzed using liquid chromatography-tandem mass spectrometry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!