Introduction: The aims of this study were to evaluate (1) grasping forces with the application of a tactile feedback system in vivo and (2) the incidence of tissue damage incurred during robotic tissue manipulation. Robotic-assisted minimally invasive surgery has been shown to be beneficial in a variety of surgical specialties, particularly radical prostatectomy. This innovative surgical tool offers advantages over traditional laparoscopic techniques, such as improved wrist-like maneuverability, stereoscopic video displays, and scaling of surgical gestures to increase precision. A widely cited disadvantage associated with robotic systems is the absence of tactile feedback.
Methods And Procedure: Nineteen subjects were categorized into two groups: 5 experts (six or more robotic cases) and 14 novices (five cases or less). The subjects used the da Vinci with integrated tactile feedback to run porcine bowel in the following conditions: (T1: deactivated tactile feedback; T2: activated tactile feedback; and T3: deactivated tactile feedback). The grasping force, incidence of tissue damage, and the correlation of grasping force and tissue damage were analyzed. Tissue damage was evaluated both grossly and histologically by a pathologist blinded to the sample.
Results: Tactile feedback resulted in significantly decreased grasping forces for both experts and novices (P < 0.001 in both conditions). The overall incidence of tissue damage was significantly decreased in all subjects (P < 0.001). A statistically significant correlation was found between grasping forces and incidence of tissue damage (P = 0.008). The decreased forces and tissue damage were retained through the third trial when the system was deactivated (P > 0.05 in all subjects).
Conclusion: The in vivo application of integrated tactile feedback in the robotic system demonstrates significantly reduced grasping forces, resulting in significantly less tissue damage. This tactile feedback system may improve surgical outcomes and broaden the use of robotic-assisted minimally invasive surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4851934 | PMC |
http://dx.doi.org/10.1007/s00464-015-4602-2 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Department of Materials Science, National Engineering Lab for TFT-LCD Materials and Technologies, Fudan University, Shanghai 200433, China.
Tactile sensation and recognition in the human brain are indispensable for interaction between the human body and the surrounding environment. It is quite significant for intelligent robots to simulate human perception and decision-making functions in a more human-like way to perform complex tasks. A combination of tactile piezoelectric sensors with neuromorphic transistors provides an alternative way to achieve perception and cognition functions for intelligent robots in human-machine interaction scenarios.
View Article and Find Full Text PDFJBJS Essent Surg Tech
January 2025
Department of Orthopaedic Surgery, Montefiore Medical Center, Bronx, New York.
Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.
Description: The procedure can be completed in a standard operating theater without the need for special instruments.
Biomedicines
December 2024
Neuromodulation Center and Center for Clinical Research Learning, Spaulding Rehabilitation Hospital and Massachusetts General Hospital, Harvard Medical School, Boston, MA 02115, USA.
Background/objectives: Haptic technology has transformed interactions between humans and both tangible and virtual environments. Despite its widespread adoption across various industries, the potential therapeutic applications of this technology have yet to be fully explored.
Methods: A systematic review of randomized controlled trials (RCTs) and randomized crossover trials was conducted, utilizing databases such as PubMed, Embase, Cochrane Library, and Web of Science.
Sci Rep
December 2024
Department of Urology, The Jikei University School of Medicine, Kashiwa Hospital, Kashiwashita 163-1, Kashiwa, Chiba, 277-8567, Japan.
To evaluate the safety and efficacy of the Saroa Surgical Robot System in robot-assisted laparoscopic radical prostatectomy (RARP). We enrolled 60 patients who underwent RARP using either the Saroa (n = 9) or da Vinci Xi (n = 51) systems at Jikei University Kashiwa Hospital from January 2022 to March 2024. We compared preoperative characteristics, perioperative outcomes, complications, and postoperative urinary continence at three months between the two groups.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
EMG feedback improves force control of a myoelectric hand prosthesis by conveying the magnitude of the myoelectric signal back to the users via tactile stimulation. The present study aimed to test if this method can be used by a participant with a high-level amputation, and whose muscle used for prosthesis control (pectoralis major) was not intuitively related to hand function. Vibrotactile feedback was delivered to the participant's torso, while the control was tested using EMG from three different muscles.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!