The majority of previous studies on hereditary neuropathy with liability to pressure palsies (HNPP) were focused on peripheral nerves, whereas cerebral alterations in HNPP have been less attended to. In this work, Diffusion tensor imaging (DTI) was used to detect the changes in WM, especially in the normal-appearing white matter (NAWM) in HNPP patients for its sensitivity in probing the microstructure of WM, the sensitive metric was searched for probing cerebral alterations and the regional distribution of cerebral abnormalities was identified. Twelve HNPP patients and 12 age- and gender-matched healthy controls underwent the conventional MRI, DTI scan, and electrophysiological examination. The conventional MRI images were first analyzed to identify abnormal intense regions and the NAWM regions. NAWM refers to the white matter regions that do not include the lesions on conventional MRI. The apparent diffusion coefficient and fractional anisotropy (FA) values of the NAWM were then measured and compared between patient and control groups. The sensitivity and specificity of 3 methods and the cerebral regional distribution of MR signal abnormalities were further analyzed. Hyperintense foci were observed on T2 weighted image and fluid attenuated inversion recovery images in 6 patients. Compared to the controls, FA values of the patients were significantly lower in bilateral frontal, orbitofrontal, and temporal NAWMs; whereas the electrophysiological examination results of patients and controls exhibited no statistically significant difference. The sensitivity of FA value was higher than that of electrophysiological examination and conventional MRI. The majority of abnormal signals on conventional MRI images and abnormal FA values were located in the frontal and temporal lobes. The results of our study show cerebral WM changes in HNPP patients. FA value in DTI has been shown to be sensitive to the cerebral microstructural changes in HNPP. The frontal lobe is the predilection site that is most involved in HNPP.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4985427 | PMC |
http://dx.doi.org/10.1097/MD.0000000000001909 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.
The use of conventional contrast agents in computed tomography (CT) and magnetic resonance (MR) imaging is often limited in patients with chronic kidney disease (CKD) due to potential nephrotoxicity. Ferumoxytol, originally developed for iron supplementation, has emerged as a promising alternative MR contrast agent that is safer for patients with CKD. This study aims to present our center's experience with ferumoxytol as a contrast agent in CKD patients.
View Article and Find Full Text PDFCarbon fibre reinforced polyetheretherketone (CFR-PEEK) implants have gained interest because of reported biomechanical advantages and radio-lucent properties. The aim of this study was to evaluate the role of CFR-PEEK nails in patients with metastatic bone disease (MBD). We performed a retrospective cohort study evaluating patients with MBD undergoing intramedullary (IM) nailing for prophylaxis or fixation of pathological fractures using CFR- PEEK or titanium implants.
View Article and Find Full Text PDFJ Urol
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO.
Purpose: Conventional prostate magnetic resonance imaging has limited accuracy for clinically significant prostate cancer (csPCa). We performed diffusion basis spectrum imaging (DBSI) prior to biopsy and applied artificial intelligence models to these DBSI metrics to predict csPCa.
Materials And Methods: Between February 2020 and March 2024, 241 patients underwent prostate MRI that included conventional and DBSI-specific sequences prior to prostate biopsy.
Magn Reson Med
January 2025
MRI Research Centre, Physics, University of New Brunswick, Fredericton, New Brunswick, Canada.
Purpose: Magnetic resonance elastography (MRE) provides detailed maps of tissue stiffness, helping to diagnose various health conditions, but requires the use of expensive clinical MRI scanners. Our approach utilizes compact, cost-effective portable MR sensors that offer bulk characterization of material properties in a region of interest close to the surface (within 1-2 cm). This accessible instrument could enable routine monitoring and prevention of diseases not readily evaluated with conventional tools.
View Article and Find Full Text PDFJ Occup Health
January 2025
Department of Occupational and Environmental Health, Faculty of Pharmaceutical Sciences, Tokyo University of Science, Noda, Japan.
Bromopropane was introduced commercially as an alternative to ozone-depleting and global warming solvents. The identification of 1-bromopropane neurotoxicity in animal experiments was followed by reports of human cases of 1-bromopropane toxicity. In humans, the most common clinical features of 1-bromopropane neurotoxicity are decreased sensation, weakness in extremities, and walking difficulties.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!