Computational fluid dynamics modelling in cardiovascular medicine.

Heart

Department of Cardiovascular Science, University of Sheffield, Sheffield, UK Insigneo Institute for In Silico Medicine, Sheffield, UK Department of Cardiology, Sheffield Teaching Hospitals NHS Trust, Sheffield, UK.

Published: January 2016

This paper reviews the methods, benefits and challenges associated with the adoption and translation of computational fluid dynamics (CFD) modelling within cardiovascular medicine. CFD, a specialist area of mathematics and a branch of fluid mechanics, is used routinely in a diverse range of safety-critical engineering systems, which increasingly is being applied to the cardiovascular system. By facilitating rapid, economical, low-risk prototyping, CFD modelling has already revolutionised research and development of devices such as stents, valve prostheses, and ventricular assist devices. Combined with cardiovascular imaging, CFD simulation enables detailed characterisation of complex physiological pressure and flow fields and the computation of metrics which cannot be directly measured, for example, wall shear stress. CFD models are now being translated into clinical tools for physicians to use across the spectrum of coronary, valvular, congenital, myocardial and peripheral vascular diseases. CFD modelling is apposite for minimally-invasive patient assessment. Patient-specific (incorporating data unique to the individual) and multi-scale (combining models of different length- and time-scales) modelling enables individualised risk prediction and virtual treatment planning. This represents a significant departure from traditional dependence upon registry-based, population-averaged data. Model integration is progressively moving towards 'digital patient' or 'virtual physiological human' representations. When combined with population-scale numerical models, these models have the potential to reduce the cost, time and risk associated with clinical trials. The adoption of CFD modelling signals a new era in cardiovascular medicine. While potentially highly beneficial, a number of academic and commercial groups are addressing the associated methodological, regulatory, education- and service-related challenges.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4717410PMC
http://dx.doi.org/10.1136/heartjnl-2015-308044DOI Listing

Publication Analysis

Top Keywords

cfd modelling
16
cardiovascular medicine
12
computational fluid
8
fluid dynamics
8
modelling cardiovascular
8
cfd
7
modelling
6
cardiovascular
5
dynamics modelling
4
medicine paper
4

Similar Publications

Physical anatomical models constructed from medical images are valuable research tools for evaluating patient-specific clinical circumstances. For example, 3D models replicating a patient's internal anatomy in the cardiovascular system can be used to validate Computational Fluid Dynamics (CFD) models, which can then be used to identify potential hemodynamic consequences of surgical decisions by providing insight into how blood and vascular tissue mechanics may contribute to disease progression and post-operative complications. Patient-specific models have been described in the literature; however, rapid prototyping models that achieve anatomical accuracy, optical transparency, and thin-walled compliance in a cost and time-effective approach have proven challenging.

View Article and Find Full Text PDF

Iliac Vein Compression Syndrome (IVCS) is a common risk factor for deep vein thrombosis in the lower extremities. The objective of this study was to investigate whether employing a porous medium model to simulate the compressed region of an iliac vein could improve the reliability and accuracy of Computational Fluid Dynamics (CFD) analysis outcomes of IVCS. Pre-operative Computed Tomography (CT) scan images of patients with IVCS were utilized to reconstruct models illustrating both the compression and collateral circulation of the iliac vein.

View Article and Find Full Text PDF

Experimental dataset of a model-scale ship in calm water and waves.

Data Brief

February 2025

Maritime Engineering Research Group, School of Engineering, University of Southampton, SO16 7QF UK.

This article presents data derived from a series of experiments conducted on a scaled model ship, examining its performance in both calm water and regular waves. The acquisition of high-quality experimental data is essential for refining Computational Fluid Dynamics (CFD) simulations and modifying analytical methods to evaluate the powering performance of ships. Despite notable advancements in numerical models, there exists a corresponding imperative to elevate the precision of measurements and insights obtained from towing tank tests.

View Article and Find Full Text PDF

The use of air-jet dry powder inhalers (DPIs) offers a number of advantages for the administration of pharmaceutical aerosols, including the ability to achieve highly efficient and potentially targeted aerosol delivery to the lungs of children using the oral or trans-nasal routes of administration. To better plan targeted lung delivery of pharmaceutical aerosols with these inhalers, more information is needed on the extrathoracic (ET) depositional loss in pediatric subjects when using relatively small (e.g.

View Article and Find Full Text PDF

The design of the flow field structure for bipolar plates significantly influences the output performance of proton exchange membrane fuel cells (PEMFCs). Adding baffles in the flow channels can enhance the transportation of reactants and electrochemical performance of the PEMFCs. In this study, three types of baffles with different shapes and sizes were designed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?