Background: Mitral isthmus is often targeted as a part of stepwise approach during radiofrequency ablation for persistent atrial ablation. Acute success rate in achieving the mitral isthmus block is only modest, late reconduction rate is relatively high and, consequently, incomplete lesion may be proarrhythmic. We describe the first-in-man experience with successful MI ablation by bipolar RF energy delivery.

Case Presentation: A 64-year-old caucasian man after two previous ablation procedures for drug resistant atrial fibrillation in recent four years, which included pulmonary vein isolation and linear left atrial lesions, was referred for the treatment of recurrent perimitral flutter. Despite the third attempt to create bidirectional block at the mitral isthmus region, we were not even able to stop the arrhythmia by aggressive unipolar radiofrequency ablation both from the left atrium and coronary sinus, because of deeply embedded slow conducting channel probably around the vein of Marshall. Arrhythmia was finally terminated and the block was achieved by bipolar radiofrequency ablation between two irrigated-tip catheters positioned at the left atrial endocardium and contralaterally inside the coronary sinus.

Conclusion: Bipolar radiofrequency energy delivery can be an option for ablation of perimitral flutter resistant to standard unipolar radiofrequency ablation. This may improve clinical outcome of patients undergoing non-pharmacological treatment for persistent atrial fibrillation. The safety and efficacy of this technique has to be confirmed in future studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4625938PMC
http://dx.doi.org/10.1186/s12872-015-0132-zDOI Listing

Publication Analysis

Top Keywords

radiofrequency ablation
16
bipolar radiofrequency
12
perimitral flutter
12
mitral isthmus
12
ablation
9
persistent atrial
8
atrial fibrillation
8
left atrial
8
unipolar radiofrequency
8
radiofrequency
5

Similar Publications

Background: A novel contact force (CF) sensing catheter with a mesh-shaped irrigation tip (TactiFlexTM SE, Abbott), is expected to provide safe and effective radiofrequency ablation. Our previous study revealed that the TactiFlex catheter needs a higher power for pulmonary vein isolation (PVI) due to the long tip length. This study aimed to examine the feasibility and safety of a 50 W ablation with the TactiFlex for PVI of atrial fibrillation (AF).

View Article and Find Full Text PDF

Background: Integration of preprocedural imaging techniques in ventricular tachycardia (VT) ablation may improve the identification of arrhythmogenic substrates, particularly relevant for patients with nonischemic cardiomyopathy (NICM) with sub-optimal outcomes. We assessed the impact of advanced preprocedural imaging on the safety and long-term efficacy of radiofrequency catheter ablation (RCA) for VT, comparing patients with NICM and ischemic cardiomyopathy (ICM).

Methods: In this prospective, single-center study, consecutive patients referred for scar-related VT ablation underwent multidetector computed tomography (MDCT) and late gadolinium enhancement cardiac magnetic resonance (LGE-CMR).

View Article and Find Full Text PDF

Background: Few clinical studies of atrial fibrillation (AF) have focused on Asian patients; data are lacking on current mapping and ablation strategies in the Asia Pacific region (APAC).

Objective: The HD Mapping Observational Study (NCT04022954) was designed to characterize electroanatomic mapping (EAM) with market-released high-density mapping (HDM) catheters in subjects with AF in APAC.

Methods: Subjects undergoing HDM and indicated for radiofrequency ablation (RFA) to treat AF were prospectively enrolled in APAC.

View Article and Find Full Text PDF

Background/objectives: Very high-power and short-duration (vHPSD) ablation with QDOT MICRO™ facilitates speedy and safe ablation for pulmonary vein isolation. A brief time interval between ablating two neighboring sites with vHPSD may potentially influence the size and geometry of the lesions. This study evaluates lesion formation when delivering adjacent applications using vHPSD at various inter-lesion times (ILTs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!