Two-photon laser-scanning microscopy enables to record neuronal network activity in three-dimensional space while maintaining single-cellular resolution. One of the proposed approaches combines galvanometric x-y scanning with piezo-driven objective movements and employs hardware feedback signals for position monitoring. However, readily applicable methods to quantify the accuracy of those feedback signals are currently lacking. Here we provide techniques based on contact-free laser reflection and laser triangulation for the quantification of positioning accuracy of each spatial axis. We found that the lateral feedback signals are sufficiently accurate (defined as <2.5 µm) for a wide range of scan trajectories and frequencies. We further show that axial positioning accuracy does not only depend on objective acceleration and mass but also its geometry. We conclude that the introduced methods allow a reliable quantification of position feedback signals in a cost-efficient, easy-to-install manner and should be applicable for a wide range of two-photon laser scanning microscopes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4605029 | PMC |
http://dx.doi.org/10.1364/BOE.6.003678 | DOI Listing |
J Comput Assist Tomogr
January 2025
Department of Radiology, George Washington University Hospital, Washington, DC.
The next step in the evolution of static 3-dimensionally (3D) printed models may be the creation of "smart" models, where subcomponents can be seamlessly interacted with through a feedback mechanism, with potential applications in trainee education and patient counseling. Considering the complexity of the ventricular and cisternal systems, they were chosen for segmentation, using Materialize InPrint with outward hollowing using 2.5-mm wall thickness.
View Article and Find Full Text PDFFiber-optic vibration sensors have been studied widely owing to their anti-electromagnetic interference, corrosion resistance, and ease of integration and distribution. Previous reports primarily focused on the frequency detection of vibration signals. However, the amplitude sensitivity, noise-equivalent amplitude (NEA), and stability determine the sensing precision and accuracy of the device.
View Article and Find Full Text PDFThe self-homodyne detection (SHD) is a promising solution to achieve low-cost and low-power-consumption fiber-optic communications. In this work, we propose and demonstrate a high-capacity spatial-division multiplexing (SDM) system with SHD technology by employing single-mode multi-core fibers (SM-MCFs), where the fan-in/fan-out (FIFO) 3D photonic devices are designed and fabricated based on the femtosecond laser direct writing technique, enabling high-efficiency coupling between single-mode fibers (SMFs) and SM-MCFs. The FIFO 3D photonic devices, serving as the SDM (de)multiplexer, facilitate superior performance of low insertion loss and low inter-channel crosstalk.
View Article and Find Full Text PDFSci Rep
January 2025
School of ECE, Adama Science and Technology University, Adama, Ethiopia.
This paper details the hardware implementation of a Universal Converter controlled by an Artificial Neural Network (ANN), utilizing key components such as six Insulated Gate Bipolar Transistors (IGBTs), two inductors, and two capacitors for energy storage and voltage smoothing. A Digital Signal Processor (DSP) serves as the core controller, processing real-time input and feedback signals, including voltage and current measurements, to dynamically manage five operational modes: rectifier buck, inverter boost, DC-DC buck, DC-DC boost, and AC voltage control. The pre-trained ANN algorithm generates pulse-width modulation (PWM) signals to control the switching of the IGBTs, optimizing timing and duty cycles for efficient operation.
View Article and Find Full Text PDFCell Biol Toxicol
January 2025
Department of Oral Anatomy and Physiology, Hospital of Stomatology, Jilin Provincial Key Laboratory of Oral Biomedical Engineering, Jilin University, Changchun, 130021, China.
Novel strategies to disrupt tumor progression have emerged from studying the interactions between tumor cells and tumor-associated macrophages (TAMs). However, the molecular mechanisms of interactions between tumor cells and TAMs underlying oral squamous cell carcinoma (OSCC) progression have not been fully elucidated. This study explored the molecular mechanism of the HSP27/IL-6 axis in OSCC chemoresistance, invasion, and migration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!