A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Core Needle Biopsy Wash Optimization: Enabling Specimen Integrity for both Cytological and Histological Evaluation. | LitMetric

Background: The recovery of cells after washing core needle biopsies represents an under-utilized approach to extend the diagnostic capacity of these diminutive specimens. Recovery of these cells can be dedicated for molecular studies so that the biopsy itself can be used apropos for its intended purpose, diagnosis. Non-enzymatic and enzymatic reagents have the potential to increase the number of cells dissociating from the tissue core, but can also negatively impact the quality of the tissue itself.

Materials And Methods: Three different means (phosphate-buffered saline, a non-enzymatic and an enzymatic solution) were used to wash core needle biopsies. The washed cells were recovered by traditional preparatory methods and evaluated for cellularity and cytomorphology. The post-washed cores were processed by formalin fixation, paraffin embedding and evaluated for integrity and morphological quality.

Results: The enzymatic solution damaged both the cytological and tissue specimens, while the saline and non-enzymatic process allowed for the comparable recovery of cells and tissue for evaluation.

Conclusion: Adequate numbers of cells are dissociated from the tissue core when needle biopsies are washed. The recovery and preservation of cells and tissue for morphological interpretation was optimal when solutions devoid of enzymes were used for washing.

Download full-text PDF

Source

Publication Analysis

Top Keywords

core needle
16
recovery cells
12
needle biopsies
12
non-enzymatic enzymatic
8
tissue core
8
saline non-enzymatic
8
enzymatic solution
8
biopsies washed
8
cells tissue
8
cells
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!