Femtosecond lasers allow for simultaneous detection of multiple absorption lines of a specimen over a broad spectral range of infrared or visible light with a single spectroscopic measurement. Here, we present an 8-THz bandwidth, 0.5-GHz resolution scheme of Fourier-transform spectroscopy using an Er-doped fiber femtosecond laser. A resolving power of 1.6 × 10(4) about a 1560-nm center wavelength is achieved by sweeping the pulse repetition rate of the light source on a fiber Mach-Zehnder interferometer configured to capture interferograms with a 0.02-fs temporal sampling accuracy through a well-stabilized 60-m unbalance arm length. A dual-servo mechanism is realized by combining a mechanical linear stage with an electro-optic modulator (EOM) within the fiber laser cavity, enabling stable sweeping control of the pulse repetition rate over a 1.0-MHz scan range with 0.4-Hz steps with reference to the Rb clock. Experimental results demonstrate that the P-branch lines of the H(13)CN reference cell can be observed with a signal-to-noise ratio reaching 350 for the most intense line.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4621541PMC
http://dx.doi.org/10.1038/srep15726DOI Listing

Publication Analysis

Top Keywords

pulse repetition
12
repetition rate
12
fourier-transform spectroscopy
8
spectroscopy er-doped
8
er-doped fiber
8
fiber femtosecond
8
femtosecond laser
8
sweeping pulse
8
fiber
4
laser sweeping
4

Similar Publications

Introduction: Tumor tissues exhibit significantly lower oxygen partial pressure compared to normal tissues, leading to hypoxia in the tumor microenvironment and result in resistance to tumor treatments. Strategies to mitigate hypoxia include enhancing blood perfusion and oxygen supply, for example,by decomposing hydrogen peroxide within the tumor. Improving hypoxia in the tumor microenvironment could potentially improve the efficacy of cancer treatments.

View Article and Find Full Text PDF

Background: Concurrent exercise (CE), an emerging exercise modality characterized by sequential bouts of aerobic (AE) and resistance exercise (RE), has demonstrated acute benefits on executive functions (EFs) and neuroelectric P3 amplitude. However, the effect of acute CE on inhibitory control, a sub-component of EFs, and P3 amplitude remains inconclusive. Moreover, exploring the mechanisms underlying the effects of acute exercise on EFs contributes to scientific comprehension, with lactate recognized as a crucial candidate positively correlated with EFs.

View Article and Find Full Text PDF

Knee osteoarthritis (OA) is the most prevalent form of osteoarthritis and a leading cause of chronic pain in adults. This study aimed to compare the short-term effects of extracorporeal shock wave therapy (ESWT), low-level laser therapy (LLLT), and pulsed electromagnetic field therapy (PEMF) on pain, function, and quality of life in patients with knee OA. A hundred and twenty patients with Kellgren-Lawrence grade 2-3 knee OA were randomized into four groups: ESWT (once a week for three sessions), LLLT (twice a week for eight sessions), PEMF (twice a week for eight sessions), and a control group with 30 patients in each group.

View Article and Find Full Text PDF

This study analyzed the acute and time-course changes following one resistance training (RT) set (1SET) and three sets (3SET) on hemodynamic and physical performance parameters in individuals with different cognitive impairment levels. Thirty-nine individuals (22 women and 17 men aged 80 ± 9 years) grouped by cognitive impairment (mild [MILD], moderate [MOD], and severe [SEV]) randomly performed two protocols, each separated by one week, of 1SET or 3SET of 10 repetitions. Before (PRE), immediately (POST), and 72 h after (POST72) protocols, the participants performed the following measurements: systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), 1-kg medicine ball throw (MBT) distance, five-repetition sit-to-stand (STS) time, and handgrip strength (HGS).

View Article and Find Full Text PDF

Atomic force microscopy-infrared spectroscopy (AFM-IR) is a photothermal scanning probe technique that combines nanoscale spatial resolution with the chemical analysis capability of mid-infrared spectroscopy. Using this hybrid technique, chemical identification down to the single molecule level has been demonstrated. However, the mechanism at the heart of AFM-IR, the transduction of local photothermal heating to cantilever deflection, is still not fully understood.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!