A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multicenter analytical performance evaluation of a fully automated anti-Müllerian hormone assay and reference interval determination. | LitMetric

Objectives: Anti-Müllenria hormone (AMH) is an established biomarker for assessing ovarian reserve and predicting response to controlled ovarian stimulation. Its routine clinical use is hampered by the variability and low-throughput of available enzyme-linked immunosorbent assays (ELISA). The presented study examined if a fully automated AMH electrochemiluminescence assay (ECLIA; Elecsys® AMH assay, Roche Diagnostics) was suitable for measuring AMH levels in healthy women and in those diagnosed with polycystic ovary syndrome (PCOS).

Design And Methods: Five European laboratories evaluated the Elecsys® AMH assay independently under routine conditions over eight months. Within-run imprecision, repeatability, intermediate precision, linearity and functional sensitivity were assessed. The Elecsys® AMH assay was compared to a manual ELISA microtiter plate format test (AMH Gen II ELISA, modified version; Beckman Coulter Inc.) using 1729 routine serum samples. AMH reference intervals were determined in 887 healthy women with regular menstrual cycle aged 20–50 years, and 149 women diagnosed with PCOS.

Results: The fully automated Elecsys® AMH assay showed excellent precision, linearity, and functional sensitivity. The coefficient of variation was 1.8% for repeatability and 4.4% for intermediate precision. Values measured with the Elecsys® AMH assay were highly correlated with the manual ELISA method (modified version) but 24–28% lower. Reference intervals showed the expected AMH decline with age in healthy women and increased AMH levels in women with PCOS.

Conclusions: The Elecsys® AMH assay demonstrated good precision under routine conditions, and is suitable for determining AMH levels in serum and lithium-heparin plasma.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiochem.2015.10.008DOI Listing

Publication Analysis

Top Keywords

elecsys® amh
24
amh assay
24
amh
14
fully automated
12
amh levels
12
healthy women
12
assay
8
women diagnosed
8
routine conditions
8
intermediate precision
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!