Role of the paraventricular nucleus in the reflex diuresis to pulmonary lymphatic obstruction in rabbits.

Can J Physiol Pharmacol

a Department of Physiology, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi, India.

Published: January 2016

The changes in urine flow and renal sympathetic nerve activity (RSNA) due to pulmonary lymphatic obstruction (PLO) were examined in anesthetized, artificially ventilated New Zealand white rabbits. PLO was produced by pressurizing an isolated pouch created in the right external jugular vein at the points of entry of the right lymphatic ducts. During this maneuver, urine flow increased from 8.5 ± 0.3 mL/10 min to 12 ± 0.5 mL/10 min (P < 0.0001) and RSNA increased from 24.0 ± 4 to 40.0 ± 5 μV·s (P < 0.0001). Bilateral lesioning of the paraventricular nucleus (PVN) of the hypothalamus or cervical vagotomy abolished these responses. PLO increased c-fos gene expression in the PVN. The increase in urine flow due to PLO was attenuated by muscimol and abolished by kynurenic acid microinjections into the PVN. The results show that (i) neurons in the PVN are an important relay site in the reflex arc, which is activated by PLO; and (ii) this activation is regulated by glutamatergic and partly by GABAergic input to the PVN.

Download full-text PDF

Source
http://dx.doi.org/10.1139/cjpp-2015-0109DOI Listing

Publication Analysis

Top Keywords

urine flow
12
paraventricular nucleus
8
pulmonary lymphatic
8
lymphatic obstruction
8
ml/10 min
8
plo
5
pvn
5
role paraventricular
4
nucleus reflex
4
reflex diuresis
4

Similar Publications

4D-printed programmable sample-/eluent-actuated solid-phase extraction device for trace metal analysis.

Anal Chim Acta

January 2025

Department of Chemistry, National Chung Hsing University, Taichung City, 402202, Taiwan, ROC. Electronic address:

Background: To integrate valves, manifolds, and solid-phase extraction (SPE) columns into a compact device is technically difficult. Four-dimensional printing (4DP) technologies, employing stimuli-responsive materials in three-dimensional printing (3DP), are revolutionizing the fabrication, functionality, and applicability of stimuli-responsive analytical devices that can show time-dependent shape programming to enable more complex geometric designs and functions. However, 4D-printed stimuli-responsive actuators and valves utilized to control flowing streams in SPE applications remain rare.

View Article and Find Full Text PDF

Paracetamol (PCM) is a commonly used analgesic and antipyretic agent for humans worldwide. However, PCM overdoses or overuse can cause health issues, such as hepatoxicity. As PCM is also used for the treatment of farm animals, it is essential to monitor these residues in animal-derived matrices at risk-based sites in order to minimize the intake of PCM through the food chain.

View Article and Find Full Text PDF

Introduction And Objectives: Laser vaporization techniques have emerged as a prominent alternative to transurethral prostate resection in managing benign prostatic obstruction (BPO). This study focuses on assessing the effectiveness of the ejaculatory preserving laser vaporization of the prostate technique compared to the conventional non-ejaculatory approach in managing BPO.

Patients And Methods: Our study was performed between August 2022 and September 2023.

View Article and Find Full Text PDF

How infusion fluids are distributed and eliminated is of importance to how much and how fast they should be administered. This manuscript applies population pharmacokinetic modeling to intravenous infusions of crystalloid fluid, which is a common therapy in hospital care and mandatory during surgery. The analysis was based on the hemodilution and urine output measured during and after 262 infusions of 1647 ± 461 mL (mean ± SD) of fluid over 30 min in adults.

View Article and Find Full Text PDF

Fluorescent microsphere-based strip for sensitive and quantitative detection of etomidate and metomidate.

Analyst

January 2025

International Joint Research Laboratory for Biointerface and Biodetection, and School of Food Science and Technology, Jiangnan University, Wuxi, People's Republic of China.

In this research, we fabricated a sensitive monoclonal antibody (mAb) 2C3 that targeted etomidate (ET) and metomidate (MT) to establish a lateral-flow immunoassay (LFIA) that incorporated fluorescent microsphere sensors, enabling both the qualitative and quantitative detection of ET and MT within 10 min. Analysis indicated that the visual colorimetric values for ET and MT in water samples were 0.3 μg kg, respectively, with quantitative detection ranges of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!