Effective therapeutic agents are lacking for the prevention and reversal of vascular leak, a frequent pathophysiologic result of inflammatory processes such as acute respiratory distress syndrome (ARDS) and sepsis. We previously demonstrated the potent barrier-enhancing effects of related compounds sphingosine 1-phosphate (S1P), the pharmaceutical agent FTY720, and its analog (S)-FTY720 phosphonate (Tys) in models of inflammatory lung injury. In this study, we characterize additional novel FTY720 analogs for their potential to reduce vascular leak as well as utilize them as tools to better understand the mechanisms by which this class of agents modulates permeability. Transendothelial resistance (TER) and labeled dextran studies demonstrate that (R)-methoxy-FTY720 ((R)-OMe-FTY), (R)/(S)-fluoro-FTY720 (FTY-F), and β-glucuronide-FTY720 (FTY-G) compounds display in vitro barrier-enhancing properties comparable or superior to FTY720 and S1P. In contrast, the (S)-methoxy-FTY720 ((S)-OMe-FTY) analog disrupts lung endothelial cell (EC) barrier integrity in TER studies in association with actin stress fiber formation and robust intracellular calcium release, but independent of myosin light chain or ERK phosphorylation. Additional mechanistic studies with (R)-OMe-FTY, FTY-F, and FTY-G suggest that lung EC barrier enhancement is mediated through lipid raft signaling, Gi-linked receptor coupling to downstream tyrosine phosphorylation events, and S1PR1-dependent receptor ligation. These results provide important mechanistic insights into modulation of pulmonary vascular barrier function by FTY720-related compounds and highlight common signaling events that may assist the development of novel therapeutic tools in the prevention or reversal of the pulmonary vascular leak that characterizes ARDS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chemphyslip.2015.10.004 | DOI Listing |
JACC Clin Electrophysiol
December 2024
Kansas City Heart Rhythm Institute and Research Foundation, Kansas City, Kansas, USA. Electronic address:
Left atrial appendage occlusion (LAAO) has become an important therapeutic target for stroke prevention in patients with nonvalvular atrial fibrillation. Over the past 2 decades, several advancements in LAAO devices (percutaneous and surgical) have been made for stroke prevention and arrhythmia therapy. However, there are several unanswered questions regarding optimal patient selection, the preferred LAAO approach and device, the management of periprocedural and postprocedural complications, including pericardial effusion, device-related thrombus, and device leaks.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
Yale Cardiovascular Research Center, Department of Internal Medicine, Yale University School of Medicine, New Haven, CT, USA.
Purpose: Alteration of visual acuity in wet age-related macular degeneration (AMD) is mostly driven by vascular endothelial growth factor A (VEGF-A)-induced edema from leaky newly forming blood vessels below the retina layers. To date, all therapies aimed at alleviation of this process have relied on inhibition of VEGF-A activity. Although effective in preventing vascular leak and edema, this approach also leads to the loss of normal vasculature and multiple related side effects.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Toronto Lung Transplant Program, Toronto General Hospital, Toronto, Canada.
Ex vivo lung perfusion (EVLP) is used to evaluate donor lungs prior to lung transplantation. Development of pulmonary edema during EVLP is generally thought to represent inflammatory breakdown of the air-fluid barrier and these lungs are declined for transplant. We present the case of a donor lung that underwent stapled wedge resection during cold storage for air leak and the subsequent development of profound (∼650 mL) pulmonary edema around the staple line during EVLP.
View Article and Find Full Text PDFCancers (Basel)
December 2024
Department of Hepatopancreaticobiliary, Endocrine and Transplantation Surgery, Antwerp University Hospital, 2650 Edegem, Belgium.
: The robotic approach is an appealing way to perform minimally invasive pancreaticoduodenectomy. We compare robotic cases' short-term and oncological outcomes to a historical cohort of open cases. : Data were collected in a prospective database between 2016 and 2024; complications were graded using the ISGPS definition for the specific pancreas-related complications and the Clavien-Dindo classification for overall complications.
View Article and Find Full Text PDFColorectal Dis
January 2025
Colorectal Surgery Unit, General Surgery Department, Marqués de Valdecilla University Hospital, Santander, Spain.
Aim: Complete mesocolic excision (CME) is an oncologically driven technique for treating right colon cancer. While laparoscopic CME is technically demanding and has been associated with more complications, the robotic approach might reduce morbidity. The aim of this study was to assess the safety of stepwise implementation of robotic CME.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!