Purpose: The aim of this clinical trial was to investigate changes in stroke volume variability (SVV) and left ventricular end-diastolic volume (LVEDV) after a fluid bolus of crystalloid or colloid using real-time three-dimensional transesophageal echocardiography (3D-TEE) and the Vigileo-FloTrac™ system.

Materials And Methods: After obtaining Institutional Review Board approval, and informed consent from the research participants, 22 patients undergoing scheduled peripheral vascular bypass surgery were enrolled in the study. The patients were randomly assigned to receive 500 mL of hydroxyethyl starch (HES; HES group, n=11) or normal saline (Saline group, n=11) for fluid replacement therapy. SVV was measured using the Vigileo-FloTrac system. LVEDV, stroke volume, and cardiac output were measured by 3D-TEE. The measurements were performed over 30 minutes before and after the fluid bolus in both groups.

Results: SVV significantly decreased after fluid bolus in both groups (HES group, 14.7%±2.6% to 6.9%±2.7%, P<0.001; Saline group, 14.3%±3.9% to 8.8%±3.1%, P<0.001). LVEDV significantly increased after fluid loading in the HES group (87.1±24.0 mL to 99.9±27.2 mL, P<0.001), whereas no significant change was detected in the Saline group (88.8±17.3 mL to 91.4±17.6 mL, P>0.05). Stroke volume significantly increased after infusion in the HES group (50.6±12.5 mL to 61.6±19.1 mL, P<0.01) but not in the Saline group (51.6±13.4 mL to 54.1±12.8 mL, P>0.05). Cardiac output measured by 3D-TEE significantly increased in the HES group (3.5±1.1 L/min to 3.9±1.3 L/min, P<0.05), whereas no significant change was seen in the Saline group (3.4±1.1 L/min to 3.3±1.0 L/min, P>0.05).

Conclusion: Administration of colloid and crystalloid induced similar responses in SVV. A higher plasma-expanding effect of HES compared to normal saline was demonstrated by the significant increase in LVEDV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4598218PMC
http://dx.doi.org/10.2147/IJGM.S89939DOI Listing

Publication Analysis

Top Keywords

stroke volume
12
fluid bolus
12
normal saline
8
hydroxyethyl starch
8
volume variability
8
left ventricular
8
group n=11
8
fluid
5
volume
5
fluid loading
4

Similar Publications

Development of a Self-Deploying Extra-Aortic Compression Device for Medium-Term Hemodynamic Stabilization: A Feasibility Study.

Adv Sci (Weinh)

December 2024

Graduate School of Biomedical Engineering, Faculty of Engineering, and Tyree Institute of Health Engineering (IHealthE), UNSW Sydney, Kensington Campus, Sydney, NSW, 2052, Australia.

Hemodynamic stabilization is crucial in managing acute cardiac events, where compromised blood flow can lead to severe complications and increased mortality. Conditions like decompensated heart failure (HF) and cardiogenic shock require rapid and effective hemodynamic support. Current mechanical assistive devices, such as intra-aortic balloon pumps (IABP) and extracorporeal membrane oxygenation (ECMO), offer temporary stabilization but are limited to short-term use due to risks associated with prolonged blood contact.

View Article and Find Full Text PDF

The correlation between Fischer's ratio and the risk of cardiac dysfunction in heart failure patients.

BMC Cardiovasc Disord

December 2024

Department of Cardiovascular Medicine, Rui Jin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, People's Republic of China.

Backgrounds: Due to the high mortality and hospitalization rate in chronic heart failure (HF), it is of great significance to study myocardial nutrition conditions. Amino acids (AAs) are essential nutrient metabolites for cell development and survival. This study aims to investigate the associations and prognostic value of plasma branched-chain amino acid/aromatic amino acid ratio (Fischer's ratio, FR) in patients with left ventricular ejection fraction (LVEF) ≤ 50%.

View Article and Find Full Text PDF

We developed a simple quantifiable scoring system that predicts aneurysmal subarachnoid hemorrhage (aSAH) mortality, delayed cerebral ischemia (DCI), and modified Rankin scale (mRS) outcomes using readily available SAH admission data with SAH volume (SAHV) measured on computed tomography (CT). We retrospectively analyzed a cohort of 277 patients with aSAH admitted at our Comprehensive Stroke Center at Mayo Clinic in Jacksonville, Florida, between January 5, 2012, and February 24, 2022. We developed a mathematical radiographic model SAHV that measures basal cisternal SAH blood volume using a derivation of the ABC/2 ellipsoid formula (A = width/thickness, B = length, C = vertical extension) on noncontrast CT, which we previously demonstrated is comparable to pixel-based manual segmentation on noncontrast CT.

View Article and Find Full Text PDF

Discontinuation rates, clinical effects and provocation factors of SGLT-2 inhibitor in the real world.

Sci Rep

December 2024

Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.

Sodium-glucose cotransporter 2 (SGLT-2) inhibitors are the only medications that improve clinical outcomes regardless of baseline left ventricular ejection fraction. Despite the recognized effectiveness of SGLT-2 inhibitors, there remains a paucity of research on the discontinuation of these medications. The objective of this study is to analyze the rate of discontinuation of SGLT-2 inhibitors, to evaluate the impact of discontinuation on the clinical outcome, and to identify the factors associated with discontinuation.

View Article and Find Full Text PDF

Off-Pump Coronary Artery Bypass Grafting is Overutilized.

Semin Thorac Cardiovasc Surg

December 2024

Department of Cardiac Surgery, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA 90048. Electronic address:

Off-pump coronary artery bypass grafting (CABG), developed to avoid the potential complications of cardiopulmonary bypass, remains a subject of debate. Studies have demonstrated that off-pump CABG is associated with higher rates of incomplete revascularization, inferior graft patency, and increased reintervention rates compared to on-pump CABG, leading to worse outcomes. The theoretical neuroprotective and renal-protective benefits associated with off-pump CABG have not been definitively proven, with stroke and renal failure rates similar to those of on-pump CABG in both short- and long-term follow-up.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!