The Effect of Electrode Designs Based on the Anatomical Heart Location for the Non-Contact Heart Activity Measurement.

J Med Syst

Department of Biomedical Engineering, College of Biomedical & Health Science, Konkuk University, 268 Chungwondaero, Chungju-si, Chungcheongbuk-do, 380-701, South Korea.

Published: December 2015

This research is an extension of a previous research [1] on the different effects of sensor location that is relatively suitable for heart rate sensing. This research aimed to elucidate the causes of wide variations in heart rate measurements from the same sensor position among subjects, as observed in previous research [1], and to enhance designs of the inductive textile electrode to overcome these variations. To achieve this, this study comprised two parts: In part 1, X-ray examinations were performed to determine the cause of the wide variations noted in the findings from previous research [1], and we found that at the same sensor position, the heart activity signal differed with slight differences in the positions of the heart of each subject owing to individual differences in the anatomical heart location. In part 2, three types of dual-loop-type textile electrodes were devised to overcome variations in heart location that were confirmed in part 1 of the study. The variations with three types of sensor designs were compared with that with a single-round type of electrode design, by using computer simulation and by performing a t-test on the data obtained from the experiments. We found that the oval-oval shaped, dual-loop-type textile electrode was more suitable than the single round type for determining morphological characteristics as well as for measuring appropriate heart activity signals. Based on these results, the oval-oval, dual-loop-type was a better inductive textile electrode that more effectively overcomes individual differences in heart location during heart activity sensing based on the magnetic-induced conductivity principle.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10916-015-0339-7DOI Listing

Publication Analysis

Top Keywords

heart location
16
heart activity
16
previous [1]
12
textile electrode
12
heart
11
anatomical heart
8
heart rate
8
wide variations
8
variations heart
8
sensor position
8

Similar Publications

Background: The mechanistic association between the hydraulic forces generated during contrast injection and the risk of coronary injury is poorly understood. In this study, we sought to evaluate whether contrast injections increase intracoronary pressures beyond resting levels and estimate the risk of hydraulic propagation of coronary dissections.

Methods: This is a prospective, single-arm, multicenter study that included patients with nonculprit, non-flow-limiting coronaries.

View Article and Find Full Text PDF

Background: Unlike non-rheumatic atrial fibrillation (AF), where left atrial thrombus (LAT) is predominantly confined to the left atrial appendage (LAA), a significant proportion of LAT in rheumatic AF occurs within the left atrial cavity (LAC). However, LAC thrombosis in rheumatic AF has not been extensively studied. This study aimed to evaluate the prevalence of LAT and its subtypes and identify potential predictors of LAT.

View Article and Find Full Text PDF

Background: Hypertension is a serious chronic disease that can significantly lead to various cardiovascular diseases, affecting vital organs such as the heart, brain, and kidneys. Our goal is to predict the risk of new onset hypertension using machine learning algorithms and identify the characteristics of patients with new onset hypertension.

Methods: We analyzed data from the 2011 China Health and Nutrition Survey cohort of individuals who were not hypertensive at baseline and had follow-up results available for prediction by 2015.

View Article and Find Full Text PDF

"A Bridge-over-the Bar": A Novel Strategy to Prevent Paravalvular Regurgitation during Mitral Valve Replacement for Severe Mitral Annular Calcifications.

Ann Thorac Cardiovasc Surg

January 2025

Division of Pediatric and Adult Congenital Cardiac Surgery, Maria Fareri Children's Hospital, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA.

Mitral annular calcifications have been known to increase complexity during mitral valve replacement (MVR). Standard procedure requires decalcification followed by reconstruction of the mitral annulus prior to placing the prosthesis. While this is the ideal technique, it is not feasible in every patient due to the associated risks.

View Article and Find Full Text PDF

Cerebral microbleeds (CMBs) are small, hypointense hemosiderin deposits in the brain measuring 2-10 mm in diameter. As one of the important biomarkers of small vessel disease, they have been associated with various neurodegenerative and cerebrovascular diseases. Hence, automated detection, and subsequent extraction of clinically useful metrics (e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!