Percutaneous radiofrequency ablation (RFA) is a minimally invasive technique that destroys cancer cells by heat. The heat results from focusing energy in the radiofrequency spectrum through a needle. Amongst others, this can enable the treatment of patients who are not eligible for an open surgery. However, the possibility of recurrent liver cancer due to incomplete ablation of the tumor makes post-interventional monitoring via regular follow-up scans mandatory. These scans have to be carefully inspected for any conspicuousness. Within this study, the RF ablation zones from twelve post-interventional CT acquisitions have been segmented semi-automatically to support the visual inspection. An interactive, graph-based contouring approach, which prefers spherically shaped regions, has been applied. For the quantitative and qualitative analysis of the algorithm's results, manual slice-by-slice segmentations produced by clinical experts have been used as the gold standard (which have also been compared among each other). As evaluation metric for the statistical validation, the Dice Similarity Coefficient (DSC) has been calculated. The results show that the proposed tool provides lesion segmentation with sufficient accuracy much faster than manual segmentation. The visual feedback and interactivity make the proposed tool well suitable for the clinical workflow.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4612735 | PMC |
http://dx.doi.org/10.1038/srep15373 | DOI Listing |
Sensors (Basel)
January 2025
Department of Mechanical Engineering, Politecnico di Milano, Via Giuseppe La Masa 1, 20156 Milan, Italy.
Radiofrequency ablation (RFA) is a minimally invasive procedure that utilizes localized heat to treat tumors by inducing localized tissue thermal damage. The present study aimed to evaluate the temperature evolution and spatial distribution, ablation size, and reproducibility of ablation zones in ex vivo liver, kidney, and lung using a commercial device, i.e.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
January 2025
Interventional Radiology, The Royal Marsden, 203 Fulham Road, London, SW36JJ, UK.
Purpose: Contrast-enhanced CT (CECT) may be performed immediately following microwave liver ablation for assessment of ablative margins. However, practices and protocols vary among institutions. Here, we compare a standardized bolus-tracked biphasic CECT protocol and compare this with a single venous phase fixed delay protocol for ablation zone (AZ) assessment.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
Power Electronics Research Centre, School of Engineering, University of Galway, Galway, Ireland.
Purpose: Pulsed electrical field (PEF) ablation is an energy-based technique used to treat a range of cancers by irreversible electroporation (IRE). Our objective was to use computational and plant-based models to characterize the electric field distribution and ablation zones induced with a commercial 8-needle array-based applicator intended for treatment of skin cancer when high-frequency IRE (H-FIRE) pulses are applied. Electric field characterisation of this device was not previously assessed.
View Article and Find Full Text PDFCirculation
January 2025
City St. George's, University of London, UK (M.C.W., A.C.L., M.M.S.).
Background: Current outcomes from catheter ablation for scar-dependent ventricular tachycardia (VT) are limited by high recurrence rates and long procedure durations. Personalized heart digital twin technology presents a noninvasive method of predicting critical substrate in VT, and its integration into clinical VT ablation offers a promising solution. The accuracy of the predictions of digital twins to detect invasive substrate abnormalities is unknown.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
Division of Cardiology, Peter Munk Cardiac Centre, University Health Network, Toronto, Ontario, Canada.