Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The purpose of this study was to compare patient comfort and preference between the use of Icare tonometer and Goldmann applanation tonometer for the measurement of intraocular pressure (IOP). This was a prospective study carried out at the Eye clinic of the University College Hospital, Ibadan on volunteers aged 18 years and above. Demographic information of the participants was collected using a proforma. All participants had Icare tonometry and Goldmann applanation tonometry (GAT) performed on them in sequence within a 15-min period. After the measurements, participants were asked to report their assessment of the level of comfort with each method and to state their preferred choice for IOP measurement. One hundred subjects participated in the study; 45 (45 %) were males, and the mean age was 47.1 (± 17.4) years. Forty-three subjects (43 %) reported that Icare was either much more comfortable or more comfortable than GAT, while 31 (31 %) stated that Goldmann applanation was either much more or more comfortable. Twenty-six participants (26 %) reported that the level of comfort was the same with the two instruments. With regard to which of the instruments will be preferred for IOP check at another clinic visit, 53 (53 %) of the respondents preferred the Goldmann applanation tonometer. Some of the participants preferred GAT because they believed it was more sophisticated, while the main reported reason for preferring Icare was the stinging sensation of the anesthetic eye drop when using GAT. Although more participants reported the Icare tonometer to be more comfortable, the Goldmann tonometer was preferred by majority of the respondents.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10792-015-0139-6 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!