A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Impact of 68Ga-DOTATATE PET/CT Imaging on Management of Patients with Neuroendocrine Tumors: Experience from a National Referral Center in the United Kingdom. | LitMetric

Unlabelled: (68)Ga-DOTATATE PET/CT scanning is a widely accepted method for imaging of neuroendocrine tumors. This cross-sectional study was performed to review the first 8 y of patient data from a large (68)Ga-DOTATATE PET/CT database in order to establish the impact of the modality on patient treatment and survival.

Methods: Demographic data, clinical outcome, survival, and change in management after (68)Ga-DOTATATE PET/CT were evaluated.

Results: Between May 2005 and August 2013, 1,258 (68)Ga-DOTATATE PET/CT scans were obtained in 728 patients with confirmed or suspected neuroendocrine tumors. In most patients, the primary site was located in the midgut (26.4%). Analysis of NET grading in patients with known histopathologic data revealed that 35.7% had NET grade G1, 12.2% G2, and 8.7% G3. The most common indications for (68)Ga-DOTATATE PET/CT were follow-up (24.4%) and initial tumor staging (23.4%). Of the 1,258 (68)Ga-DOTATATE PET/CT scans completed, 75.7% were positive and 24.3% negative; there were 14 false-positive and 29 false-negative scans. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 97%, 95.1%, 96.6%, 98.5%, and 90.4%, respectively. In 40.9% of patients, the treatment plan was changed after the scans, owing mainly to new, unexpected findings. Statistically significant differences in survival were shown between patients with G1, G2, and G3 grade tumors (P < 0.0001) and also between patients with bone metastasis versus patients with soft-tissue metastasis (P < 0.0001).

Conclusion: (68)Ga-DOTATATE PET/CT scanning is safe and influences management in a large proportion of patients. Prognosis was dependent on tumor grade, and the presence of bone metastasis was associated with worse overall survival.

Download full-text PDF

Source
http://dx.doi.org/10.2967/jnumed.115.166017DOI Listing

Publication Analysis

Top Keywords

68ga-dotatate pet/ct
32
neuroendocrine tumors
12
patients
9
pet/ct
8
pet/ct scanning
8
1258 68ga-dotatate
8
pet/ct scans
8
bone metastasis
8
68ga-dotatate
7
impact 68ga-dotatate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!