Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The flow diverter (FD) is a device aimed at reconstructing the parent artery and occluding an aneurysm. We performed a propensity score-matched analysis to compare safety and efficacy between the FD and stent-assisted coiling.
Methods: A database review was conducted to identify patients with large and giant unruptured aneurysms (aneurysms located in the ACA, MCA, or PCA were excluded) treated with the FD or stent-assisted coiling. A propensity score, representing the probability of using the FD, was generated for each aneurysm using the relevant patient and aneurysmal variables. Angiographic results, complications, and clinical outcomes were compared.
Results: Forty-five aneurysms treated with the FD (FD alone: 32; FD+Coils: 13) and 45 treated with stent-assisted coiling were matched. The rate of complete occlusion was significantly (P = 0.0002) higher in the FD cohort than the conventional stent cohort at the 6-month follow-up. The FD cohort achieved greater improvement (P < 0.0001) and a lower rate of recurrence (P = 0.0001). The rate of periprocedural complications was similar, as was the proportion of patients who attained mRS ≤ 2 at discharge and at the 6-month follow-up.
Conclusions: Our findings provide reliable evidence demonstrating that the FD may be a preferred treatment option for large and giant unruptured aneurysms.
Key Points: • Flow Diverter provided a higher complete occlusion rate at 6-month follow-up. • Flow Diverter achieved more progress occlusion and less recurrence. • Compared with the conventional stents, procedure-related morbidity of Flow Diverter was similar. • Flow Diverter is a preferred treatment for large and giant unruptured aneurysms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-015-4052-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!