Severity: Warning
Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 144
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To establish corneal cross-linking (CXL) with riboflavin and UV-A in in the mouse cornea in vivo and to develop tools to measure the biomechanical changes observed.
Methods: A total of 55 male C57BL/6 wild-type mice (aged 5 weeks) were divided into 14 groups. Standard CXL parameters were adapted to the anatomy of the mouse cornea, and riboflavin concentration (0.1%-0.5%) and fluence series (0.09-5.4 J/cm²) were performed on the assumption of the endothelial damage thresholds. Untreated and riboflavin only corneas were used as controls. Animals were killed at 30 minutes and at 1 month after CXL. Corneas were harvested. Two-dimensional (2D) biomechanical testing was performed using a customized corneal holder in a commercially available stress-strain extensometer/indenter. Both elastic and viscoelastic analyses were performed. Statistical inference was performed using t-tests and specific mathematical models fitted to the experimental stress-strain and stress-relaxation data. Adjusted P values by the method of Benjamini and Hochberg are reported.
Results: For all CXL treatment groups, stress-relaxation showed significant differences (P < 0.0001) after 120 seconds of constant strain application, with cross-linked corneas maintaining a higher stress (441 ± 40 kPa) when compared with controls (337 ± 39 kPa). Stress-strain analysis confirmed these findings but was less sensitive to CXL-induced changes: at 0.5% of strain, cross-linked corneas remained at higher stress (778 ± 111 kPa) when compared with controls (659 ± 121 kPa).
Conclusions: Cross-linking was induced in the mouse cornea in vivo, and its biomechanical effect successfully measured. This could create opportunities to study molecular pathways of CXL in transgenic mice.