Effect-site concentrations of remifentanil causing bradycardia in hypnotic and non-hypnotic patients.

J Clin Monit Comput

Department of Anesthesiology, Nantan General Hospital, Yagi Ueno 25, Nantan City, Kyoto, 629-0141, Japan.

Published: December 2016

Although the induction of anaesthesia with remifentanil often causes bradycardia, the relationship between the effect-site concentration (Ce) of remifentanil and instantaneous heart rate (HR) has remained unclear. The present study examined the relationship between instantaneous HR and remifentanil Ce at the induction of anaesthesia with and without propofol hypnosis, to facilitate safe management of anaesthesia induction with remifentanil. Instantaneous HR was calculated every 5 s using an electrocardiographic real-time analysis system (MemCalc/Makin2; GMS, Tokyo, Japan). At the beginning of anaesthesia induction, continuous infusion of remifentanil (1 μg min kg) preceded hypnosis with propofol in 13 patients [non-hypnosis group; mean age, 67.8 (17.5) years], while propofol bolus (30-50 mg) was injected together with continuous remifentanil medication in 18 patients [hypnosis group; mean age, 62.9 (16.5) years]. Remifentanil Ce was estimated every 5 s using the three-compartment model proposed by Minto et al. and the relationship between estimated remifentanil Ce and instantaneous HR was examined. In the hypnosis group, HR was significantly lower than basal HR when remifentanil Ce was increased to 3.5 ng ml (p < 0.05), whereas no significant HR reduction was found in the non-hypnosis group until remifentanil Ce reached >5 ng ml (p < 0.05). The induction of anaesthesia using remifentanil with propofol hypnotics significantly reduces HR even in a low remifentanil Ce insufficient to suppress the cardiovascular response at tracheal intubation. Preparations to treat bradycardia are recommended for the safe management of anaesthesia induction when remifentanil is combined with hypnotics.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-015-9794-4DOI Listing

Publication Analysis

Top Keywords

remifentanil instantaneous
12
remifentanil
10
induction anaesthesia
8
anaesthesia induction
8
group age
8
effect-site concentrations
4
concentrations remifentanil
4
remifentanil causing
4
causing bradycardia
4
bradycardia hypnotic
4

Similar Publications

Background: In the anesthesia management of percutaneous liver tumor ablation, the requirement of analgesia is very strict. Currently, intravenous anesthesia is commonly used, such as remifentanil combined with sedative drugs. However, the pain relief is not instantaneous after increasing the dosage of remifentanil.

View Article and Find Full Text PDF

Evaluation of the analgesia nociception index for monitoring intraoperative analgesia in children.

Br J Anaesth

August 2018

Department of Anaesthesia and Intensive Care, Robert Debré University Hospital, Paris, France; Denis Diderot University, Paris, France; DHU Protect INSERM U 1141, Robert Debré University Hospital, Paris, France. Electronic address:

Background: Intraoperative analgesia is still administered without guidance. Anaesthetists decide upon dosing on the basis of mean population opioid pharmacological studies and in response to variations in haemodynamic status. However, those techniques have been shown to be imprecise.

View Article and Find Full Text PDF

Effect-site concentrations of remifentanil causing bradycardia in hypnotic and non-hypnotic patients.

J Clin Monit Comput

December 2016

Department of Anesthesiology, Nantan General Hospital, Yagi Ueno 25, Nantan City, Kyoto, 629-0141, Japan.

Although the induction of anaesthesia with remifentanil often causes bradycardia, the relationship between the effect-site concentration (Ce) of remifentanil and instantaneous heart rate (HR) has remained unclear. The present study examined the relationship between instantaneous HR and remifentanil Ce at the induction of anaesthesia with and without propofol hypnosis, to facilitate safe management of anaesthesia induction with remifentanil. Instantaneous HR was calculated every 5 s using an electrocardiographic real-time analysis system (MemCalc/Makin2; GMS, Tokyo, Japan).

View Article and Find Full Text PDF

The level of sedation in patients undergoing medical procedures evolves continuously, such as the effect of the anesthetic and analgesic agents is counteracted by pain stimuli. The monitors of depth of anesthesia, based on the analysis of the electroencephalogram (EEG), have been progressively introduced into the daily practice to provide additional information about the state of the patient. However, the quantification of analgesia still remains an open problem.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!