A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulmonary Bleeding During Right Ventricular Support After Left Ventricular Assist Device Implantation. | LitMetric

Pulmonary Bleeding During Right Ventricular Support After Left Ventricular Assist Device Implantation.

J Cardiothorac Vasc Anesth

Department of Cardiothoracic Surgery, Division of Cardiac Surgery, University Hospital Münster, Münster, Germany.

Published: June 2016

Objectives: Right heart failure still occurs in up to 20% of patients after implantation of a left ventricular assist device (LVAD). One treatment option for these patients is the implantation of a temporary right ventricular assist device (RVAD). Experimental data suggest that non-pulsatile perfusion of the lungs is associated with an increased rate of pulmonary hemorrhage. The aim of this study was to determine the incidence of pulmonary bleeding complications in these patients.

Design: Observational study.

Setting: Single center, university hospital.

Participants: This study included patients undergoing LVAD implantation for end-stage heart failure and subsequent implantation of a temporary right ventricular support system.

Interventions: In this study, 25 patients who underwent LVAD and additional temporary RVAD implantation were screened for pulmonary bleeding complications.

Measurements And Main Results: The mean Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level at the time of LVAD implantation was 2.84. All patients experienced severe right ventricular failure (tricuspid annular plane systolic excursion [TAPSE], 10.16±26.3 mm) and severe pulmonary hypertension (right atrial [RA] pressure, 56.21±15.58 mmHg). Average duration of right ventricular support was 11.12±7.20 days, with right ventricular support being administered to 14 patients for more than 7 days. Seventeen patients were weaned successfully from right ventricular support after a mean support duration of 5 days. Five patients developed pulmonary bleeding complications, diagnosed using computed tomography scan and bronchoscopy. All bleeding occurred after postoperative day 7 and was associated with RVAD flow of more than 4 L/min within 24 hours before bleeding occurred.

Conclusions: The data presented in this study suggested that right ventricular support for more than 7 days and a blood flow greater than 4 L/min were associated with pulmonary bleeding complications. This should be taken into consideration when temporary right ventricular support after LVAD implantation is planned.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2015.07.012DOI Listing

Publication Analysis

Top Keywords

ventricular support
28
pulmonary bleeding
20
ventricular assist
12
assist device
12
temporary ventricular
12
bleeding complications
12
lvad implantation
12
ventricular
11
support
9
left ventricular
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!