Background: Accurate HIV testing in pregnancy is critical to the prevention of mother to child transmission of HIV infection and linkages to other preventive strategies.

Aims And Objectives: This study determined the sensitivity, specificity negative and positive predictive value of serial rapid testing of HIV among pregnant women in Nnewi, south east Nigeria.

Methodology: This was a comparative descriptive study conducted over a 4-month period. Serial rapid testing algorithm was compared with conventional ELISA testing after obtaining informed consents from the pregnant women. All positive and discordant results were confirmed with western blot HIV test. Participants also completed a questionnaire. Data analysis was done using SPSS version 20.

Result: A total of 166 pregnant women participated in this study. The mean age of the participants was 29 ± 4.3 years. The HIV prevalence was highest in the 25-29 years category. This was also the modal age category. Majority of the women were multiparous. The prevalence of HIV infection was 12 %. The sensitivity, specificity, negative and positive predictive value of serial rapid HIV testing was 95, 100, 99.3 and 100 % respectively.

Conclusion: The sensitivity of the serial rapid test algorithm was high but still lower than the WHO recommended 99 % and above. The 100 % specificity and positive predictive value makes it a good diagnostic test strategy. There is need for regular review of HIV test kits and policy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4603774PMC
http://dx.doi.org/10.1186/s13104-015-1454-8DOI Listing

Publication Analysis

Top Keywords

serial rapid
20
pregnant women
16
hiv test
12
positive predictive
12
hiv
10
rapid hiv
8
test algorithm
8
south east
8
hiv testing
8
hiv infection
8

Similar Publications

The scientific discipline of endocrinology has been invaluable to our understanding of the estrous cycle. In the second half of the twentieth century the development of immunoassay technologies provided a rapid and sensitive method to quantify circulating concentrations of reproductive hormones and relate them to stage of the estrous cycle and physiological status of the animal. Ovarian ultrasonography provided the ability to track the growth and regression of ovarian structures within the same animal across the estrous cycle in real time and, in combination with hormonal profiling, accurately identify mechanisms regulating the estrous cycle and early pregnancy.

View Article and Find Full Text PDF

Background: Immune effector cell-associated neurotoxicity syndrome (ICANS) can be a severe, life-threatening toxicity following CAR T-cell therapy. While currently evaluated by the immune effector cell-associated encephalopathy (ICE) score, not all patients have changes in their ICE score and not all signs and symptoms of neurotoxicity are captured.

Methods: We conducted a prospective, single center cohort pilot study to evaluate a novel, rapid neurocognitive assessment tool (CART-NS) in detecting early, subtle neurotoxicity prior to the onset of ICANS and any deterioration in the ICE score.

View Article and Find Full Text PDF

Chimeric antigen receptor T cells (CART) targeting CD19 through CD28.ζ signaling induce rapid lysis of leukemic blasts, contrasting with persistent tumor control exhibited by 4-1BB.ζ-CART.

View Article and Find Full Text PDF

Background And Aims: Uncontrollable gaming behavior is a core symptom of Internet Gaming Disorder (IGD). Attentional bias towards game-related cues may contribute to the difficulty in regulating online gaming behavior. However, the context-specific attentional bias and its cognitive mechanisms in individuals with IGD have not been systematically investigated.

View Article and Find Full Text PDF

Serially coupled columns enhance rapid separation and predictive interaction understanding of 93 fentanyl analogs.

Anal Chim Acta

January 2025

College of Pharmacy, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea. Electronic address:

Background: The simplicity of synthesis methods has facilitated the illegal manufacture of various fentanyl analogs, leading to numerous fatal overdoses worldwide, particularly in North America. Fentanyl analogs with similar structures are difficult to distinguish due to their fragmentation patterns, making separation using chromatography essential. Additionally, because fentanyl analogs are lethal even in trace amounts, they are easily smuggled, and commonly used fentanyl test strips often fail to detect them due to their low sensitivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!