A computer model of a patient-specific clinical (177)Lu-DOTATATE therapy dosimetry system is constructed and used for investigating the variability of renal absorbed dose and biologically effective dose (BED) estimates. As patient models, three anthropomorphic computer phantoms coupled to a pharmacokinetic model of (177)Lu-DOTATATE are used. Aspects included in the dosimetry-process model are the gamma-camera calibration via measurement of the system sensitivity, selection of imaging time points, generation of mass-density maps from CT, SPECT imaging, volume-of-interest delineation, calculation of absorbed-dose rate via a combination of local energy deposition for electrons and Monte Carlo simulations of photons, curve fitting and integration to absorbed dose and BED. By introducing variabilities in these steps the combined uncertainty in the output quantity is determined. The importance of different sources of uncertainty is assessed by observing the decrease in standard deviation when removing a particular source. The obtained absorbed dose and BED standard deviations are approximately 6% and slightly higher if considering the root mean square error. The most important sources of variability are the compensation for partial volume effects via a recovery coefficient and the gamma-camera calibration via the system sensitivity.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/60/21/8329DOI Listing

Publication Analysis

Top Keywords

absorbed dose
12
dose bed
12
gamma-camera calibration
8
system sensitivity
8
uncertainty propagation
4
propagation spect/ct-based
4
spect/ct-based renal
4
renal dosimetry
4
dosimetry 177lu
4
177lu peptide
4

Similar Publications

Variable relative biological effectiveness (RBE) of carbon radiotherapy may be calculated using several models, including the microdosimetric kinetic model (MKM), stochastic MKM (SMKM), repair-misrepair-fixation (RMF) model, and local effect model I (LEM), which have not been thoroughly compared. In this work, we compared how these four models handle carbon beam fragmentation, providing insight into where model differences arise. Monoenergetic and spread-out Bragg peak carbon beams incident on a water phantom were simulated using Monte Carlo.

View Article and Find Full Text PDF

Epidemiological studies have suggested that following long-term, low-dose daily aspirin (LTLDA) administration for more than 5 years at 75-100 mg/day, 20-30% of patients (50-80 years old) had a lower risk of developing colorectal cancer (CRC) and about the same proportion in developing iron deficiency anemia (IDA). In cases of IDA, an increase in iron excretion is suspected, which is caused by aspirin chelating metabolites (ACMs): salicylic acid, salicyluric acid, 2,5-dihydroxybenzoic acid, and 2,3-dihydroxybenzoic acid. The ACMs constitute 70% of the administered aspirin dose and have much longer half-lives than aspirin in blood and tissues.

View Article and Find Full Text PDF

Review of Cadmium Bioaccumulation in Fish Exposed to Cadmium.

Toxics

December 2024

Department of Marine Life Science, Jeju National University, Jeju 63243, Republic of Korea.

Cadmium (Cd) is a highly toxic substance in the aquatic ecosystem, which can represent a high risk to fish. Fish are exposed to heavy metals through waterborne and dietary pathways, some of which are absorbed by the body and can accumulate in specific tissues without being eliminated. The accumulation varies depending on several factors such as dose, exposure route, exposure time, metal types, and biological status of the fish, and environmental parameters such as DO, salinity, pH, and metal speciation.

View Article and Find Full Text PDF

The formation of an aluminosilicate gel structure made of alkali-activated materials (AAMs) was conducted through an alkali-activation reaction of the solid precursors (fly ash, metakaolin, and wood ash). Fly and wood ash are by-products of the burning process of coal and wood, respectively. Alkali-activated materials of aluminosilicate origin, made from the different ashes, fly and wood, are very attractive research targets and can be applied in various technological fields due to their thermal stability, resistance to thermal shock, high porosity, high sustainability, and finally, low energy loss during production.

View Article and Find Full Text PDF

Assessment of the effectiveness of Monte Carlo Simulation for dose control at the Moroccan Boukhalef ionization facility.

Appl Radiat Isot

January 2025

Department of Physics, Nuclear Physics and Techniques Team, Faculty of Science, Ibn Tofail University, Kenitra, Morocco.

Controlling the absorbed dose received by a target is a major challenge encountered during ionizing radiation applications. For experimentally measuring absorbed dose, dosimetric systems are used. On the other hand, in addition to experimental methods of dose measurement, there are other alternatives for calculating absorbed doses, these are numerical methods based on the Monte Carlo method which are very sophisticated and widely used throughout the world.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?