A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and Evaluation of a SYBR Green-Based Real-Time Multiplex RT-PCR Assay for Simultaneous Detection and Serotyping of Dengue and Chikungunya Viruses. | LitMetric

Chikungunya virus (CHIKV) and dengue virus (DENV) have emerged as the two most important arbovirus diseases of global health significance. Similar clinical manifestations, transmission vectors, geographical distribution, and seasonal correlation often result in misdiagnosis of chikungunya infections as dengue cases and vice versa. In this study, we developed a rapid and accurate laboratory confirmative method to simultaneously detect, quantify, and differentiate DENV serotypes 1, 2, 3, and 4 and CHIKV. This SYBR Green I-based one-step multiplex real-time RT-PCR assay is highly sensitive and specific for CHIKV and DENV. Melting temperature analysis of PCR amplicons was used to serotype DENV and to differentiate from CHIKV. The detection limit of the assay was 20, 10, 50, 5, and 10 RNA copies/reaction for DENV-1, DENV-2, DENV-3, DENV-4, and CHIKV, respectively. Our assay did not cross-react with a panel of viruses that included other flaviviruses, alphaviruses, influenza viruses, human enteroviruses, and human coronaviruses. The feasibility of using this assay for clinical diagnosis was evaluated in DENV- and CHIKV-positive patient sera. Accordingly, the assay sensitivity for DENV-1, DENV-2, DENV-3, DENV-4, and CHIKV was 89.66%, 96.67%, 96.67%, 94.12%, and 95.74%, respectively, with 100% specificity. These findings confirmed the potential of our assay to be used as a rapid test for simultaneous detection and serotyping of DENV and CHIKV in clinical samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7106138PMC
http://dx.doi.org/10.1016/j.jmoldx.2015.06.008DOI Listing

Publication Analysis

Top Keywords

rt-pcr assay
8
simultaneous detection
8
detection serotyping
8
denv-1 denv-2
8
denv-2 denv-3
8
denv-3 denv-4
8
denv-4 chikv
8
assay
7
chikv
7
denv
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!