Chemical exchange saturation transfer magnetic resonance imaging (CEST-MRI) is capable of both microenvironment and molecular imaging. The optimization of scanning parameters is important since the CEST effect is sensitive to factors such as saturation power and field homogeneity. The aim of this study was to determine if the CEST effect would be altered by changing the length of readout RF pulses. Both theoretical computer simulation and phantom experiments were performed to examine the influence of readout RF pulses. Our results showed that the length of readout RF pulses has unremarkable impact on the Z-spectrum and CEST effect in both computer simulation and phantom experiment. Moreover, we demonstrated that multiple refocusing RF pulses used in rapid acquisition with relaxation enhancement (RARE) sequence induced no obvious saturation transfer contrast. Therefore, readout RF pulse has negligible effect on CEST Z-spectrum and the optimization of readout RF pulse length can be disregarded in CEST imaging protocol.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4601040PMC
http://dx.doi.org/10.1038/srep15062DOI Listing

Publication Analysis

Top Keywords

readout pulse
12
saturation transfer
12
readout pulses
12
chemical exchange
8
exchange saturation
8
length readout
8
computer simulation
8
simulation phantom
8
cest
5
readout
5

Similar Publications

Proteases, an important class of enzymes that cleave proteins and peptides, carry a wealth of potentially useful information. Devices to enable routine and cost effective measurement of their activity could find frequent use in clinical settings for medical diagnostics, as well as some industrial contexts such as detecting on-line biological contamination. In particular, devices that make use of readouts involving magnetic particles may offer distinct advantages for continuous sensing because material they release can be magnetically captured downstream and their readout is insensitive to optical properties of the sample.

View Article and Find Full Text PDF

Lack of timely prognosis of cardiovascular condition (CVC) is resulting in increased mortality across the globe. Currently, available techniques are confined to medical facilities and need the intervention of specialists. Frequently, this impedes timely treatment, driven by socioeconomic factors.

View Article and Find Full Text PDF

Donor heart machine perfusion enables avoidance of prolonged cold ischemia, however the optimal temperature is yet to be elucidated. Given that maintenance of temperature beyond ambient levels demands significant energy, we sought to determine the suitability of room-temperature perfusion preservation of neonatal/pediatric-sized (5-20 kg) piglet donor hearts. A custom device was fabricated suitable for this purpose, with continuous readout of perfusion pressure, flow rate, temperature, and oxygen saturation.

View Article and Find Full Text PDF

A Study on the Timing Sensitivity of the Transient Dose Rate Effect on Complementary Metal-Oxide-Semiconductor Image Sensor Readout Circuits.

Sensors (Basel)

November 2024

State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institution of Nuclear Technology, Xi'an 710024, China.

Complementary Metal-Oxide-Semiconductor (CMOS) image sensors (CISs), known for their high integration, low cost, and superior performance, have found widespread applications in satellite and space exploration. However, the readout circuits of pixel arrays are vulnerable to functional failures in complex or intense radiation environments, particularly due to transient γ radiation. Using Technology Computer-Aided Design (TCAD) device simulations and Simulation Program with Integrated Circuit Emphasis (SPICE) circuit simulations, combined with a double-exponential current source fault injection method, this study investigates the transient dose rate effect (TDRE) on a typical readout circuit of CISs.

View Article and Find Full Text PDF

CSL040 is a soluble, recombinant fragment of the complement receptor 1 (CR1) extracellular domain that acts as an inhibitor of all three pathways of the complement system. Systemic toxicity, toxicokinetics (TK), and pharmacodynamics (PD) of CSL040 were assessed in two-week intravenous (IV) bolus studies in Han Wistar rats and cynomolgus monkeys. Recovery from any effects was evaluated during a four-week recovery period.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!