A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Predictability in orbital reconstruction. A human cadaver study, part III: Implant-oriented navigation for optimized reconstruction. | LitMetric

Predictability in orbital reconstruction. A human cadaver study, part III: Implant-oriented navigation for optimized reconstruction.

J Craniomaxillofac Surg

Department of Oral and Maxillofacial Surgery (Head: Prof. Dr. J. de Lange), Orbital Unit, Academic Medical Centre of Amsterdam, University of Amsterdam, Academic Centre for Dentistry (ACTA), Meibergdreef 9, 1105 AZ Amsterdam ZO, The Netherlands.

Published: December 2015

Navigation-assisted orbital reconstruction remains a challenge, because the surgeon focuses on a two-dimensional multiplanar view in relation to the preoperative planning. This study explored the addition of navigation markers in the implant design for three-dimensional (3D) orientation of the actual implant position relative to the preoperative planning for more fail-safe and consistent results. Pre-injury computed tomography (CT) was performed for 10 orbits in human cadavers, and complex orbital fractures (Class III/IV) were created. The orbits were reconstructed using preformed orbital mesh through a transconjunctival approach under image-guided navigation and navigation by referencing orientating markers in the implant design. Ideal implant positions were planned using preoperative CT scans. Implant placement accuracy was evaluated by comparing the planned and realized implant positions. Significantly better translation (3.53 mm vs. 1.44 mm, p = 0.001) and rotation (pitch: -1.7° vs. -2.2°, P = 0.52; yaw: 10.9° vs. 5.9°, P = 0.02; roll: -2.2° vs. -0.5°, P = 0.16) of the placed implant relative to the planned position were obtained by implant-oriented navigation. Navigation-assisted surgery can be improved by using navigational markers on the orbital implant for orientation, resulting in fail-safe reconstruction of complex orbital defects and consistent implant positioning.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcms.2015.08.014DOI Listing

Publication Analysis

Top Keywords

implant
9
orbital reconstruction
8
implant-oriented navigation
8
preoperative planning
8
markers implant
8
implant design
8
complex orbital
8
implant positions
8
navigation
5
orbital
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!