Analysis of pre-ignited improvised incendiary devices using portable Raman.

Talanta

Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University Institute of Research in Police Sciences (IUICP), University of Alcalá, Ctra. Madrid-Barcelona km. 33.600, Alcalá de Henares, 28871 Madrid, Spain. Electronic address:

Published: November 2015

In this work, the use of a portable Raman spectrometer is evaluated for the non-invasive analysis of two types of pre-ignited improvised incendiary devices (IIDs), the classic Molotov cocktails and the chemical ignition Molotov cocktails (CIMCs). The most common ignitable liquids (ILs) used to make classic Molotov cocktails (gasoline, diesel fuel, kerosene and ethanol) were measured in seven different clear and colored glass bottles to evaluate if the container features could hamper the Raman measurements. The results showed that the portable Raman spectrometer can be employed to detect ILs in glass bottles without disturbances. Chemical changes on the ILs are produced when they are mixed with acid; therefore, to evaluate the use of the portable Raman spectrometer for the analysis of CIMCs required an investigation of how time and movement influence the measurements. Thus, two different IL-sulfuric acid mixtures commonly used to make CIMCs (gasoline-sulfuric acid and diesel fuel-sulfuric acid) were measured over time under static and motion conditions. In spite of the intense fluorescence encountered in both CIMCs, it was possible to identify the acid and the gasoline for the first hours of the reaction both in the static and motion experiments. Concerning the diesel fuel present in the CIMC, it underwent instantaneous chemical changes under both measurement conditions, showing high fluorescence that impeded its identification. In view of the results achieved, the portable Raman spectrometer can be a useful instrument for the rapid, non-invasive and safe analysis of pre-ignited IIDs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2015.06.072DOI Listing

Publication Analysis

Top Keywords

portable raman
20
raman spectrometer
16
molotov cocktails
12
analysis pre-ignited
8
pre-ignited improvised
8
improvised incendiary
8
incendiary devices
8
classic molotov
8
diesel fuel
8
glass bottles
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!