The design of an optimal gradient encoding scheme (GES) is a fundamental problem in diffusion MRI. It is well studied for the case of second-order tensor imaging (Gaussian diffusion). However, it has not been investigated for the wide range of non-Gaussian diffusion models. The optimal GES is the one that minimizes the variance of the estimated parameters. Such a GES can be realized by minimizing the condition number of the design matrix (K-optimal design). In this paper, we propose a new approach to solve the K-optimal GES design problem for fourth-order tensor-based diffusion profile imaging. The problem is a nonconvex experiment design problem. Using convex relaxation, we reformulate it as a tractable semidefinite programming problem. Solving this problem leads to several theoretical properties of K-optimal design: (i) the odd moments of the K-optimal design must be zero; (ii) the even moments of the K-optimal design are proportional to the total number of measurements; (iii) the K-optimal design is not unique, in general; and (iv) the proposed method can be used to compute the K-optimal design for an arbitrary number of measurements. Our Monte Carlo simulations support the theoretical results and show that, in comparison with existing designs, the K-optimal design leads to the minimum signal deviation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4584248 | PMC |
http://dx.doi.org/10.1155/2015/760230 | DOI Listing |
Entropy (Basel)
August 2018
College of Liberal Arts and Sciences, National University of Defense Technology, Changsha 410000, China.
Bayesian optimization (BO) based on the Gaussian process (GP) surrogate model has attracted extensive attention in the field of optimization and design of experiments (DoE). It usually faces two problems: the unstable GP prediction due to the ill-conditioned Gram matrix of the kernel and the difficulty of determining the trade-off parameter between exploitation and exploration. To solve these problems, we investigate the K-optimality, aiming at minimizing the condition number.
View Article and Find Full Text PDFBiomed Res Int
July 2016
Department of Radiation Physics, Institute of Clinical Sciences, University of Gothenburg, 41345 Gothenburg, Sweden ; Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, 41345 Gothenburg, Sweden.
The design of an optimal gradient encoding scheme (GES) is a fundamental problem in diffusion MRI. It is well studied for the case of second-order tensor imaging (Gaussian diffusion). However, it has not been investigated for the wide range of non-Gaussian diffusion models.