Orthogonal plate osteosynthesis enhances fixation stability in periprosthetic femur fractures. Another option are locking attachment plates (LAP) allowing bicortical locking screw placement lateral to the prosthesis stem. Stability of lateral plate osteosynthesis with two LAP (2LAP) was compared to anterolateral orthogonal plate osteosynthesis (OP) with one LAP in a periprosthetic femur fracture model. In six pairs of fresh frozen human femora with cemented Charnley hip prosthesis, a transverse osteotomy was set distal to the tip of the prosthesis simulating a Vancouver type B1 fracture. Each pair was instrumented using a plate tensioner with either one lateral plate and two LAP, or two orthogonal anterolateral plates and one LAP. Stiffness was determined in a four-point-bending test prior to cyclic testing (2Hz) with physiologic profile and progressively increasing load up to catastrophic construct failure. Paired t-test and Wilcoxon-signed-rank test were used for statistical evaluation at a level of significance p = 0.05. The OP construct exhibited a significantly higher number of cycles and load to failure (39,627 cycles ± 4,056; 4,463 N ± 906) compared to the 2LAP construct (32,927 cycles ± 3,487; 3,793 N ± 849), p < 0.01. Mediolateral bending and torsional stiffness of the OP (1610 N/mm ± 249; 16.9 Nm/mm ± 6.3) were significantly higher compared to 2 LAP (1077 N/mm ± 189; 12.1 Nm/mm ± 3.9), p = 0.03 for both comparisons. Orthogonal plate osteosynthesis is a valuable option in periprosthetic fracture surgery, offering increased stability compared to a single lateral plate fixed with two LAP.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.23065DOI Listing

Publication Analysis

Top Keywords

plate osteosynthesis
16
periprosthetic femur
12
orthogonal plate
12
lateral plate
12
femur fractures
8
plates lap
8
osteosynthesis lap
8
plate
7
lap
7
orthogonal
5

Similar Publications

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

Background: Multiple approaches exist for operative fixation of metacarpal fractures; with common treatments including lag screw fixation or open-reduction internal fixation (ORIF) with plates and screws. Recently, the adaptation of intramedullary screw (IMS) placement has allowed for an essentially closed approach with stable fixation and theoretically improved outcomes. Thus, we sought to compare such approaches to ultimately determine the superior method for achieving the goal of return to normal function.

View Article and Find Full Text PDF

BACKGROUND Extensor pollicis longus (EPL) tendon rupture is a potential complication following distal radius fracture, typically occurring several weeks after injury. Herein, we present a rare case of acute extensor pollicis longus tendon rupture associated with a distal radius fracture. CASE REPORT A 35-year-old woman visited our hospital with a distal radius fracture.

View Article and Find Full Text PDF

Background: Total ankle replacement (TAR) has evolved in the last decade from a procedure rife with complication and failure to a promising alternative to arthrodesis. The ability to maintain ankle joint range of motion is showing great promise in patient-reported outcomes, postsurgical pain, as well as long-term sequalae of joint fusion. Although TAR can be performed via either an anterior or lateral approach both with their own sets of benefits and potential complications, the consensus seems to be that one is no better than the other when performed by high-volume surgeons.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?